background image

 Page 3 of 6   | 04112013

User Manual: Rotomolded Portable Spray Units | English

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

 Model No.: SP-30N, SP-30NK, SP-30NV

Operation Instructions

Wearing all PPE and observing all safety precautions dictated by 

the MSDS for your chemical:

1. 

Fill the tank with the solution to be sprayed.

2.  Connect an appropriate compressed air line into the air 

inlet fitting (AP25).

3.  Squeeze the discharge trigger gun (PSG12) to begin 

spraying.

After Use Instructions:

1. 

Flush the unit with fresh water for 5 minutes.

2. 

Disconnect the air line from the air fitting (AP25) and 

relieve any pressure remaining in the system by squeezing 

the discharge trigger gun (PSG12).

3. 

Release the discharge trigger gun (PSG12) after all 

pressure has been relieved from the system. 

Maintenance Instructions:

To keep your portable unit operating properly, periodically 

perform the following maintenance procedures:

• 

Check the air pump (P56/P56K/P56V) for wear and leaks.

•  Inspect hoses for leaks or excessive wear. Make sure all 

hose clamps are in good condition and properly secured.

•  Replace filter (AFR25) in regulator (R25) as needed.
•  Check the suction tube and screen for debris and clean as 

needed.

• 

Drain compressor tank on a regular basis to ensure proper 

operation of pump.

Troubleshooting Instructions:

• 

Check to ensure that the discharge hose is uncoiled 

properly, and that there are no kinks that could obstruct 

fluid flow.

•  Check the air regulator bowl (ABR25) and air filter (AFR25) 

for debris such as water, oil, or rust particles. Clean by 

unthreading the air regulator bowl (ABR25) from the air 

regulator (R25).

•  Check the strainer (STR38-IL) for debris or other 

blockages, and clean as needed.  Replace strainer if 

damaged.  Strainer must be used.

•  If air passes through the pump (P56/P56K/P56V) without 

cycling, the pump needs to be replaced.

• 

Check for proper air pressure on the air gauge (AG100). 

The air regulator (R25) is factory set at 50 psi (3.4 bar). 

Operating range is 40 to 80 PSI (3 to 5 bar) with 2 CFM 

(56.6 l/min).  

•  If the unit operates at a reduced pressure:

•  Check the air compressor supplying the unit. If the 

pressure is less than 40 psi, turn the unit off until the 

compressor can catch up.

•  If the air supply is 50 psi (4.14 bar) or above, check 

the air gauge (AG100), which should read near 50 psi 

(4.14 bar). If the air gauge reads more or less than 50 

psi (4.14 bar), adjust the pressure by turning the knob 

on the top of the air regulator (R25).

Summary of Contents for SP-30N

Page 1: ...USER MANUAL MODEL NUMBER SP 30N SP 30NK SP 30NV AND RELATED UNITS 30 Gallon Air Operated Portable Spray Equipment English Original Instructions ...

Page 2: ... Caustic cleaners Sanitizers and Acids D Limonene may only be used with Kalrez pump Chlorine may only be used with Viton or Kalrez pump DO NOT USE All hydrocarbons Read this manual completely and understand the machine before operating or servicing it Read all instructions before installing or operating unit Always wear appropriate personal protective equipment PPE when operating or servicing unit...

Page 3: ...R25 as needed Check the suction tube and screen for debris and clean as needed Drain compressor tank on a regular basis to ensure proper operation of pump Troubleshooting Instructions Check to ensure that the discharge hose is uncoiled properly and that there are no kinks that could obstruct fluid flow Check the air regulator bowl ABR25 and air filter AFR25 for debris such as water oil or rust par...

Page 4: ...SP 30NV SSP12 AS1 VS CST5SS L DP A DFP7 see parts list for color op ons SSAXEL20 5 FWAX15 TANK 30N HNDL TANK 30N W15 CST5SS FWAX15 PVCV34FM FW3878 COT AHB 3816 HBSS1238 ST2520 PSG12 PW124 120 TANK ASSEMBLY ITEM NUMBER TANK 30N A SPRAY GUN ASSEMBLY ITEM NUMBER SGA14 HBSS1238 H38B H Available per ft SSC38 30 ft 9 m HOSE ASSEMBLY ITEM NUMBER H38 30 ...

Page 5: ...BRKT PVCV34FM P56 BRKT SCREW SSC38 SSC38 STR38 IL FWP12 EC14 2 SC1212 BPS 58SO HBSSEL1814 BPS 58SO HBSS1238 AG100 P56 P56K or P56V P14 R25 BACK PLATE Inside View BACK PLATE Outside View H38B H Available per HBSS1438 FACI14 AP25 HBBF1438 OPTIONAL COMPONENTS WATER SEPARATOR ITEM NUMBER WS 20CFM 30 ft 9 m AIR HOSE ASSEMBLY ITEM NUMBER AH30 PLUG 3 4 FWP12 HBSS1238 TW916 SSA14 AP25 ...

Page 6: ...OSE BARB 1 2mpt X 3 8 barb Tariff 8479 90 9496 HBSS1438 STAINLESS HOSE BARB 1 4 MPT X 3 8 BARB HBSSEL1814 304 STAINLESS ELBOW 1 8 INCH NPT X 1 4 INCH HOSE BARB HHPB3412 HEX HEAD POLY REDUCER BUSHING 3 4 X 1 2 P14 COUNTERSUNK PLUG HEXAGON 1 4 P56 5700 PUMP WITH SANTOPRENE SEALS INCLUDES HOSE BARBS AIR FITTING AND AIR PORT P56K 5700 PUMP WITH KALREZ SEALS INCLUDES HOSE BARBS AIR FITTING AND AIR PORT...

Reviews: