background image

15 Gallon Electric Fog/Mist Unit

User Manual

MU-AC-15N
MU-AC-15N-PSGN130

READ ALL INSTRUCTIONS BEFORE USING, OR SERVICING, THIS EQUIPMENT. KEEP THIS MANUAL IN A 

LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS.
English (Original Instructions)

Summary of Contents for MU-AC-15N

Page 1: ...Unit User Manual MU AC 15N MU AC 15N PSGN130 READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS EQUIPMENT KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS En...

Page 2: ...Product Overview 5 Product Requirements 5 Product Specifications 5 Product Components 6 3 Assembly 8 4 Operation 9 5 Troubleshooting 11 6 Parts 13 Contents V20200501 Page 2 of 14 Model MU AC 15N MU AC...

Page 3: ...T use a solution with a temperature above 100 F 37 77 C Operating the unit when damaged or leaking may result in exposure to chemical solutions serious injury or death Never use the unit if it is dama...

Page 4: ...the motor Always use a 3 wire extension cord that has a 3 blade grounding plug and is no more than 25 ft long and at least 14 gauge Operating the air compressor motor with excessive or insufficient el...

Page 5: ...r customer service department Power type Electricity Chemical pickup type Draws from pre mixed solution Number of products unit can draw from One product Suction line length diameter 3 8 in 9 5 mm ins...

Page 6: ...ck fit check valve 6 Suction line valve 7 In line strainer Product components Before you begin get to know the MU AC 15N and MU AC 15N PSGN130 components that you will need to use adjust or assemble V...

Page 7: ...n line valve 14 MGA RAC N130 wand 15 Drain plug 16 Air compressor bracket 17 120V air compressor 1HP 18 Tank 19 Air supply line 20 25 ft coiled tubing V20200501 Page 7 of 14 Model MU AC 15N MU AC 15N...

Page 8: ...lign the holes on the compressor bracket with the holes on the front tank sides 4 Fasten the screws into the bracket 5 Attach the in blue air hose from that back of the unit to the air compressor usin...

Page 9: ...discharge wand in a safe direction and open the air shut off valve at the trigger gun Then squeeze the trigger handle to begin misting Note Both discharge valves should be completely open while mistin...

Page 10: ...e any pressure remaining in the unit Once pressure is relieved release the trigger handle and close the air shut off valve at the trigger gun On model MU AC 15N Press the red and blue trigger buttons...

Page 11: ...gauge and adjust the air regulator if needed The air regulator is factory set at 50 psi Operating pressure is 50 psi Check the air compressor AC120V 1HP CAT to confirm sufficient air pressure is bein...

Page 12: ...oise Low voltage supply to the motor Check that the main voltage corresponds to specifications An extension cord that is too thin or too long can cause a voltage drop and cause the motor to overheat A...

Page 13: ...1HP CAT AG100 AP25 BVB14 CST5SS L CST5SS CT25 CV14QF S QFSOV14 DFP7 DP A H14BU H14B F H38B F P56 P56K P56V PSG N130 R25 QF1214 PSG12 TANK 15N C TANK 15NC CATBRKT W15 STR38 IL HHPB3414 PVCV34FM HBSSEL...

Page 14: ...e barb 1 4 mpt x 3 8 barb elbow HHPB3414 Hex head poly bushing 3 4 mpt x 1 4 fpt MGA RAC N130 Misting gun assembly rac gun PFN N130 P56 Pump with santoprene seals includes hose barbs air fitting and e...

Reviews: