3.2.2 Environment Requirement
Item
Requir ement
Machine hall spac e
W hen us er install mac hine frame array in
one mac hine hall, the distanc e between 2
row
of
machine
frames
should
be
1.2~1.5m and the distanc e to wall should
be no less than 0.8m
。
Machine hall floor
Electric Is olation, D ust Free
Volume rec eptivity of ground anti-static
material:1
×
10
7
~1
×
10
10
Ω
,Grounding
current limiting resistanc e: 1M
Ω
。
Floor bearing should be greater than
450Kg/m
2
。
Environment
temperature
5~40
°
C sustainable
,
0~45
°
C short time
installing
air-c onditioning
is
rec ommended
Relative humidity
20%~80% sustainable 10%~90% short
time
Pressure
86~105KPa
Door & window
Installing
rubber
strip
f or
s ealing
door-gaps and dual level glass es f or
window
W all
It can be c overed with wallpaper, or bright
less paint.
Fire protection
Fire alarm s ystem and extinguisher
Power
Requiring devic e power, air-c onditioning
power and lighting power are independent
to each other. D evic e power requires AC
power 100V-240V 50/60H z 2A Pleas e
carefully chec k bef ore running.
3.2.3 Grounding Requirement
All function modules’ good grounding designs are the base of reliability
and stability of device. Also, they are the most important guarantee of