background image

www.fmuser.org 

www.fmuser.org 

 

19 

10.1 Lamp for Modulation Cell 

10.1.1 Lamp for Power on 

        When this lamp is luminous, it means the power supply for modulation cell is normal. 

10.1.2 Lamp for Video AGC 

        When video output is controlled by AGC, this lamp is light. 

10.2 Lamp for Amplifier Cell 

10.2.1 Lamp for Power on 

        When it is power on, the voltage of 5V is supplied normally, this green lamp is luminous. 

10.2.2 Lamp for RF 

      When the RF SWITCH on the main menu is set to “ON”, this green lamp is light. 

10.2.3 Lamp for Video 

        While output power is normal, this lamp is light. 

10.2.4 Lamp for REMOTE 

        In the page of Set, if Remote is enabled, this yellow light is illuminant. 

10.2.5 Lamp for TEMP 

        When  the  amplifier  temperature  is  higher  than  70

,  if  temperature  exceeds  85

,it  will 

power off immediately. 

10.2.6    Lamp for VSWR 

        If  reflected  power  is  higher  than  2%  of  rated  power,  the  lamp  is  light;  higher  than  4%  of 

power, it will decrease output power to decrease reflected power; when it is higher than 5%, it may 

happen that: the software power off the output, or the hardware circuit switch off the power supply, 

then power on again. 

10.2.7    Lamp for GENERAL 

        If  this  lamp  is  light,  it  may  happen  that:  forward  power  is  more  than  101%  of  rated  power, 

Summary of Contents for FU-300W

Page 1: ...www fmuser org www fmuser org 1 FU 300W TV Transmitter User s Manual...

Page 2: ...ice first 2 A 50 Ohm dummy load or antenna and cable must be connected before turning power on avoiding water going into the connecters or the cable 3 Please read System Control Logic section to fully...

Page 3: ...2 Technical Specifications 5 3 System Structure and Function 6 4 Test Instrument 7 5 Test and Maintenance 8 6 Panel Function Description 8 7 Power on Sequence 9 8 System Control Logic 10 9 Direction...

Page 4: ...ether the machine has connected the ground through the wire and the lead to prevent the electric shock c Use the proper fuse Please use the stipulated type and rating fuse d Provide good ventilation T...

Page 5: ...turn on or turn off TV transmitter by remote command 2 Technical Specifications 2 1 Technical Index 2 1 1 Video Index 1 Video input impedance 75 2 Video input level 1 0Vp p 3 Video modulating rate 87...

Page 6: ...l Specifications RF output connector L16 L27 Casing Size 4U 484mm 172mm 600mm 19Inch Weight Ambient temperature 5 40 Relative Humidity 95 Sea Level Height 4500m 3 System Structure and Function This TV...

Page 7: ...power voltage current temperature and showing working status 4 Test Instrument Name Type Specification Manufacturer Television Generator TSG 271 Tektronix TV Monitoring Receiver PM5696 Philip Video Me...

Page 8: ...nd some of their technical specifications is much higher than the national standards and industry standards 5 1 Performance Test To ZHC515A family TV transmitter video index and RF index need to be te...

Page 9: ...fmuser org 9 the digital FM broadcast transmitter works at a very dirty environment for example a place with much of dust it must be to replace fans ahead of schedule 6 Panel Description 6 1 Front Pa...

Page 10: ...RF output can be controlled by RF Switch which is on the Main Page of the LCD When RF Switch is OFF turn off RF power When RF Switch is ON and the video signal input is normal turn RF power on 8 2 Rem...

Page 11: ...then pressing or key making window frame at If LCD displays picture 1 it means no video signal input If LCD displays picture 2 and video is AGC status modulating degree automatically changes to 87 5...

Page 12: ...on the front panel putting LCD Display under paging status and then pressing or key making window frame at User can press Select key entering variable status and then pressing or key achieving desirab...

Page 13: ...n the front panel putting LCD Display under paging status and then pressing or key making window frame at Frequency 543 25MHz is the video carrier frequency Channel 22ch means current channel is chann...

Page 14: ...r Power Amplifier Cell There is LCD Up key Down Key Enter key on the front panel for user to operate and view parameter of Amplifier Cell Up key Down key Enter key User can select page and save parame...

Page 15: ...2 shows main menu page This page contains the parameter as following RF SWITCH RF switch control select between ON or OFF FWD POWER forward power display only RFL POWER reflected power display only AM...

Page 16: ...ers it should to be enter the SET page FWD POWER forward power RFL POWER reflected power AMP VOLTAGE amplifier voltage DRV CURRENT current of preamp AMP CURRENT current of power amplifier TEMPERATURE...

Page 17: ...rotect Normal forward power is normal Warning forward power is higher than setting power Protected forward power is too high RF power is turned off RFL POWER Normal Warning Protect Protect H Normal re...

Page 18: ...wer is turned off TEMPERATURE Normal Warning Protect Normal temperature is normal Warning temperature is high may cause RF power drop Protected temperature is too high RF power is turned off EXIT retu...

Page 19: ...ideo While output power is normal this lamp is light 10 2 4 Lamp for REMOTE In the page of Set if Remote is enabled this yellow light is illuminant 10 2 5 Lamp for TEMP When the amplifier temperature...

Page 20: ...r this mode of equipment 11 Failure Check 11 1 Turn on the power supply but the equipment doesn t work it may The fuse is broken change the fuse The plug is not inserted tightly or contacted fault ins...