FMI WCM-48F Owners Manual And Installation Manual Download Page 17

www.fmiproducts.com

122272-01D

17

IMPORTANT:

 The glass must be allowed to 

warm slowly and evenly. Such materials as 

pitch/wax laden logs, very dry mill end lumber 

and  large  amounts  of  paper  or  cardboard 

boxes can create an excessively hot fire and 

should not be burned in this fireplace. Always 

keep the fire well back from the doors and 

never allow flames to contact the glass.

  WARNING:  Fireplaces 

equipped  with  glass  doors 

should  be  operated  only  with 

doors fully opened or doors fully 

closed. Doors, if left partly open, 

may draw gas and flame out of 

the  fireplace  opening  creating 

risks of both fire and smoke.

Cleaning Glass

Clean  glass  with  any  commercial  glass 

cleaner or soap and water. Do not use any 

abrasive material to clean glass. Do not clean 

glass with any cool water if glass is still hot 

from the fire and smoke.
A gas line or gas log lighter may be installed 

for the purpose of installing a vented or vent-

free decorative gas appliance incorporating an 

automatic shutoff device and complying with 

the S

tandard for Decorative Gas Appliances for 

Installation in Vented Fireplaces, ANSI Z21.60

 

or 

American Gas Association draft requirements 

for Gas Fired Log Lighters for Wood Burning 

Fireplaces, Draft NO. 4

 dated August, 1993.

If you wish to install an unvented (vent-free) 

gas log set, only unvented gas log sets which 

have been found to comply with the standard 

for unvented room heaters, ANSI Z21.11.2 are 

to be installed in this fireplace.

DAMPER HANDLE OPERATION

The  damper  handle  opens  and  closes  the 

damper blade and is located in the upper rear 

side of fireplace just above rear bricks. Rotate 

handle counterclockwise slightly to disengage 

from retaining bracket. Swing slowly toward 

opening of fireplace. Engage handle to sec-

ondary  bracket  located  at  front  of  fireplace 

inner wall (see Figure 27).

opeRation and Maintenance

Continued

 CAUTION: When operating 

damper door, please be aware of 

sharp edges and corners. Open 

and close damper door slowly to 

avoid injury.

 WARNING: Risk of fire! Re

-

place grate with FMI PRODUCTS, 

LLC model 109496-01 grate only. 

This grate has been designed to 

keep the operation of your fire

-

place safe and efficient.

Figure 27 - Operating Damper Handle

Damper 

Handle

Retaining 

Bracket 

(Holds 

Damper 

Door 

Closed)

Swing Door Down to Open

Swing Door 

Up to Close

Secondary 

Retaining 

Bracket 

(Holds 

Damper 

Door 

Open)

FULLY OPEN POSITION

FULLY CLOSED POSITION

Summary of Contents for WCM-48F

Page 1: ...ndards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard ThiswoodburningfireplacecomplieswithUL127 CAN ULC S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to deter mine the need to obtain a permit INSTALLER Leave this manual wi...

Page 2: ...PRODUCTS LLC in combination with a FMI PROD UCTS LLC fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces WARNING Do not install a fireplaceinsertinthisboxunless the manufacturer s instructions with ...

Page 3: ...r Using Straps Provided Hearth Spacer Required for Combustible Floor 0 to Bottom 12 Min Each Side Hearth Extension 72 X 20 Outside Air Access Location 1 5 Airspace Back and Sides 2 Chimney Airspace Clearance to Combustible Material No Combustible Material on Front Face Except for Mantel Applications Gas Line Access Location 18 Min to Perpendicular Wall Safety Continued WARNING Alwaysleaveglass doo...

Page 4: ...y at the level of the flue gas outlet see Figure 15 page 9 Framing 1 Frame the opening for the fireplace using the dimensions shown in Figures 1 and 2 2 If the fireplace is to be installed directly on carpeting tile other than ceramic or any combustible material including wood flooring the fireplace must be installed 60 875 65 7 71 5 76 375 31 625 Secure Fireplace To Hearth Spacer Using Straps Pro...

Page 5: ...Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth Extension Mantels A mantel may be installed if desired see Figure 4 Woodwork such as wood trims mantels or any other combustible material projecting from the front face must not be placed within 12 of the fireplace opening Combustible materials above 12 an...

Page 6: ...pipe sections are locked together When installing double wall snap lock chimney to gether it is important to assure joint between chimney sections is locked Check by pulling chimney upward after locking Chimney will not come apart if properly locked It is not necessary to add screws to keep chimney together exception see Figure 9 page 8 Figure 5 Outside Air Kit Secure to Collars with Metal Tape Sc...

Page 7: ...18 24 36 48 4 3 8 16 3 8 ELBOW SET ONLY 9 3 4 25 1 2 1 12 3 4 30 3 4 1 15 34 3 4 1 18 40 1 1 21 1 4 46 1 4 1 23 3 4 49 1 4 1 1 27 3 4 56 3 4 1 30 60 3 4 1 1 33 66 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 56 1 4 106 1 4 2 59 1 4 111 1 2 1 1 1 61 3 4 115 1 2 1 2 64 3 4 120 3 4 1 2 68 1 4 127 2 1 70 130 1 1 2 74 1 4 137 1 2 1 2 1 76 3 4 141 1 ...

Page 8: ... Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 Penetrating roof To maintain a 2 clearance to pipe on roof with a pitch a rectangular opening must be cut 1 Determine center point through which pipe will penetrate roof 2 Determine center point of roof Pitch is the distance the roof drops over a given span usually 12 3 Use roof opening chart Figure 12 to determine correct open...

Page 9: ...ainst open edge of flashing see Figure 14 Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 14 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Fireplace system must be terminated with listed round top or chase terminations In any case refer to installation instructions supplied with termination CAUTION Do not seal open in...

Page 10: ...10 Foot Rule Seal Opening with Refractory Cement Outside of Fireplace Gas Line Conduit Repack Insulation Incoming 1 2 Black Iron Pipe Side Firebrick Finished Side Provide Enough Threaded End for Fitting Connection Figure 18 Gas Line Installation Optional Gas Line Installation Gas line hook up should be done by your sup plier or a qualified service person Note Before you proceed make sure your gas ...

Page 11: ...ing Brick Brick Stamped Number Location Brick Housing Flanges Brick Installation IMPORTANT Installationofbrick should be done after the fire place is placed in a permanent location Each brick housing is stamped with a number full size bricks are not stamped These num bers will help identify the brick when installing It is important to install these bricks exactly as instructed Press brick firmly i...

Page 12: ... 0 0 2 S 0 0 2 S 0 0 8 S 0 1 9 S 0 1 9 S 0 1 9 S 0 2 3 S026 S027 S028 S029 S030 F U L L F U L L F U L L F U L L S 0 3 4 F050 F049 F049 F049 F049 F049 F049 F049 F049 F049 F055 F056 F053 F055 F055 F055 S021 or S006 S012 S025 S024 F054 S042 F051 F054 F050 S041 S039 S038 S037 S001 S003 S007 S022 S040 S001 S003 F U L L F U L L F U L L F U L L F U L L F U L L F U L L S 0 0 6 F U L L F U L L F U L L F U ...

Page 13: ... S014R S014W 1 S015R S015W 1 S016R S016W 1 S019R S019W 3 S020R S020W 11 S021R S021W 1 S023R S023W 1 S024R S024W 1 S025R S025W 1 S026R S026W 1 S027R S027W 1 S028R S028W 1 S029R S029W 1 S030R S030W 1 REAR UPPER REFRACTORY RED IVORY QTY FULL 112140 02 FULL 112140 06 24 F054R F054W 3 S002R S002W 1 S005R S005W 2 S006R S006W 2 S007R S007W 3 S008R S008W 1 S011R S011W 1 S013R S013W 1 S014R S014W 8 S015R S...

Page 14: ...e into piping bag making sure the smaller opening is downward and over a moist towel to avoid spilling Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Begin grouting by first doing a Filler Pass This is done by filling the joint about 3 4 full with grout mixture It is important to wor...

Page 15: ...ptional Ash Lip Kit Rail installation 1 Remove screws securing top face to firebox see Figure 22 2 Align holes on rail to be installed at top and replace screws Note Door rails are identical until spring clips are in place 3 Using remaining door rail as a template place along front row of bricks at bottom making sure rail front surface is flush with fireplace bottom face surface Mark hole centers ...

Page 16: ...rs must be fully opened before starting fire This will provide sufficient combustion air and maintain safe temperatures in firebox Figure 26 Bi Fold Glass Doors Doors Fully Closed Fireplace Front Fireplace Front Doors Fully Opened Installing Glass Doors After spring clips have been installed some adjustments may be needed Install the doors using the following steps 1 With bi fold doors completely ...

Page 17: ...laces ANSI Z21 60 orAmericanGasAssociationdraftrequirements for Gas Fired Log Lighters for Wood Burning Fireplaces Draft NO 4 dated August 1993 If you wish to install an unvented vent free gas log set only unvented gas log sets which have been found to comply with the standard for unvented room heaters ANSI Z21 11 2 are to be installed in this fireplace damper handle operation The damper handle op...

Page 18: ...y Parts Bi Fold Glass Masonry Door BDMO48E 48 Ebony BDMO48G 48 Pewter BDMO48C 48 Oiled Bronze Double Wall Pipe 12 12DM 18 12DM 24 12DM 36 12DM 48 12DM 12 12HT 18 12HT 24 12HT 36 12HT and 48 12HT 30 Offset and Return 30E 12DM and 30E 12HT Grate 109496 01 for F48 Series 123277 01 for WCM 48F Series Ember Protector 20093 Optional Outside air kit for floor installation ak4f Optional Outside Air Kit fo...

Page 19: ... Parts Continued SQUARE CHASE TOP TERMINATION STL 12D Round ToP TErminations RLT 12D and RLT 12HT Optional ASH LIP KIT Bricks AL48 Red Brick AL48I Ivory Brick Optional Hearth Spacer HS48 24 Round Woodnook DHR 24 Screen 118115 01 Rod 110146 02 Push On Nut 11418 ...

Page 20: ...122272 01 Rev D 01 10 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com ...

Reviews: