background image

www.fmiproducts.com

122274-01G

16

 WARNING: A qualified ser

-

vice person must connect heater 

to  gas  supply.  Follow  all  local 

codes.

IMPORTANT:

 See 

Connecting to Gas Supply

 

in your log set owner’s manual for details on 

gas hookup.

Note: Before you proceed, make sure your 

gas supply is turned off.

Use only a 1/2" black iron pipe and appropri

-

ate fittings. 

1.  Remove knockout indentation on refrac-

tory or firebrick wall located above refrac

-

tory  hearth  floor.  Knockout  indentation 

must be firmly tapped with any solid object 

such as a 1/2" dowel until it is released. 

Remove fragmented portions of refractory 

(see Figure 19).

2.  Remove gas line cover plate located on 

either side of fireplace and pull out insula

-

tion from gas line conduit sleeve. Save 

insulation for reuse. Replace screws.

3.  Run a 1/2" black iron gas line into fireplace 

through the rear at gas line conduit sleeve (if 

using a raised platform, add height). Provide 

sufficient gas line into fireplace chamber for 

fitting connection (see Figure 20). 

 

Note: Secure incoming gas line to wood 

framing to provide rigidity for threaded end.

4.  Repack insulation around gas line and into 

sleeve opening. Seal any gaps between 

gas line and refractory knockout hole with 

refractory cement or commercial furnace 

cement, Install the gas appliance or cap-off 

gas line if desired.

Figure 19 - Gas Line Access

Side 

Firebrick 

Finished 

Side

Brick with 

Access 

Hole

Outside of 

Fireplace

Gas Line 

Conduit

Insulation

Gas 

Conduit 

Cover

1/2" Dowel

Seal 

Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side 

Firebrick 

Finished 

Side

Provide Enough 

Threaded 

End for Fitting 

Connection

Figure 20 - Gas Line Installation

Remove 

Knockout

GAS LINE INSTALLATION

  CAUTION:  All  gas  piping 

and connections must be tested 

for leaks after the installation 

is  completed.  After  ensuring 

that the gas valve is on, apply 

soap  and  water  solution  to  all 

connections and joints. Bubbles 

forming  show  a  leak.  Correct 

all leaks at once. DO NOT USE 

AN  OPEN  FLAME  FOR  LEAK 

TESTING AND DO NOT OPER-

ATE ANY APPLIANCE IF A LEAK 

IS DETECTED. LEAK TESTING 

SHOULD BE DONE BY A QUALI-

FIED SERVICE PERSON.

Summary of Contents for VUM50

Page 1: ...al switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future referenc...

Page 2: ... fireplace size requirement DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMEN SIONS REQUIRED FOR THE INSTALLATION WARNING FOR USE ONLY WITH A LISTED GAS FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40 000 BTU H DO NOT BUILD A WOOD FIRE SAFETY This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohib...

Page 3: ...creens are closed before running installed gas log heater Replace hood with FMI PRODUCTS LLC model 109511 01 50 109511 02 42 or109511 0336 only Thishood has been designed to keep the operation of your fireplace safe and efficient 1 Do not use this firebox as a wood burning fireplace Use only decorative unvented room heaters log sets 2 Do not add extra logs or ornaments such as pine cones vermiculi...

Page 4: ...CATING FIREBOX PLANNING Plan where you will install the firebox This will save time and money later when you install the firebox Before installation consider the following 1 Where firebox will be located Allow for wall and ceiling clearances see Installa tion Clearances page 11 2 Everything needed to complete installation 3 These models CANNOT be installed in a bedroom unless maximum Btu rating of...

Page 5: ...274 01G 5 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 36 Models V UM36 and V QM36 Series 30 1 2 29 30 11 1 8 54 1 2 7 7 8 7 36 45 1 8 35 16 97 16 50 365 16 7 3 8 111 8 36 HEARTH 1 5 16 19 13 16 Ref 34 3 4 22 18 3 8 3 3 4 4 7 8 ...

Page 6: ... 6 PRODUCT SPECIFICATIONS Continued 42 MODELS Figure 2 42 Models V UM42 and V QM42 Series 4 7 8 54 1 2 7 7 8 7 36 5 16 50 42 51 1 8 32 3 8 3 3 4 30 5 16 8 3 4 13 3 5 16 9 7 16 30 11 1 8 23 13 16 Ref 1 5 16 40 3 4 25 22 1 2 42 HEARTH ...

Page 7: ...G 7 PRODUCT SPECIFICATIONS Continued 50 MODELS Figure 3 50 Models V UM50 AND V QM50 Series 365 16 50 8 3 4 13 35 16 97 16 23 13 16 Ref 1 5 16 33 40 3 4 22 1 2 50 HEARTH 59 1 8 50 7 7 8 7 30 54 1 2 11 1 8 32 3 8 3 3 4 38 5 16 4 7 8 ...

Page 8: ...et to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms WARNING This heater shall notbeinstalledinaroomorspace unlesstherequiredvolumeofin door combustion air is provided by the method described in the National Fuel Gas Code ANSI Z223 1 NFPA54 theIn...

Page 9: ...ecause the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoo...

Page 10: ...TION Log heaters installed in this firebox create warmaircurrents Thesecurrents move heat to wall surfaces next to firebox Installing firebox next tovinylorclothwallcoveringsor operating firebox where impuri ties suchas butnotlimitedto to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls or cause odors INSTALLATION NOTICE The firebox identif...

Page 11: ...ntel above built in fire box you must meet the minimum allowable clearance between mantel shelf and top of firebox opening shown in Figure 7 These are the minimum allowable mantel clearances for a safe installation Use larger clearances wherever possible to minimize the heating of objects and materials placed on the mantel CAUTION Do not allow the vent freegaslogheatertotouch or extend beyond the ...

Page 12: ...ly insert firebox into rough opening 5 Attach firebox to wall studs using nails or wood screws through holes in nailing flange see Figure 10 6 Install and properly test gas log heater Follow installation instructions included with the vent free gas log heater that is being installed IMPORTANT When finishing your firebox combustible materials such as wall board gypsum board sheet rock drywall plywo...

Page 13: ... your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be avail able from your retailer or custom built for your home 1 Assemble cabinet mantel as instructed 2 Install gas piping to firebox location See Installing Gas Line page 14 You may have to cut an access hole in the floor or wall to run gas line to firebox Make sure to locate access hole so cabinet mante...

Page 14: ...ht Face Slot Figure 14 Slots for Firebrick Walls 3 Secure the firebrick wall using 2 of the retainers provided The bracket will slip underneath the metal lip on the top of the wall and screw into the inner dome of the fireplace Figure 15 Figure 15 Installing Side Walls Retaining Bracket Leading Bricks Right Wall 4 Install the rear firebrick wall last Place the wall face side down on the hearth wit...

Page 15: ...void spilling Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints where two firebrick walls come together 6 Using a trowel remove excess grout mix ture by moving trowel in the direction of the joint Grout mixture in the joint should now be flush with brick surface If not ...

Page 16: ...ection see Figure 20 Note Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired Figure 19 Gas Line Access Side Firebrick Finished Side Brick with A...

Page 17: ...t or has a broken component please do not return it to the store Call FMI PRODUCTS LLC at 1 866 328 4537 to answer questions and replace parts under warranty Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty When calling or writing please have your model and serial numbers of your fireplace ready Model and serial number information ...

Page 18: ...www fmiproducts com 122274 01G 18 PARTS MODELS V UM SERIES AND V QM SERIES 11 10 11 13 14 15 16 14 4 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 ...

Page 19: ... Top 1 20 109457 03 Screen 36 2 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 03 Screen 36 Stainless 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 21 20806 Screen Rod 36 2 110146 03 Screen Rod 42 2 110146 02 Screen Rod 50 2 117568 03 Screen Rod 36 Stainless 2 117568 02 Screen Rod 42 Stainless 2 117568 01 Screen Rod 50 Stainless 2 22 109511 01 Hood 50 1 109511 02 Hood 42 1 ...

Page 20: ...www fmiproducts com 122274 01G 20 PARTS MODELS MODELS V UM SERIES AND V QM SERIES Picture may vary from actual 1 6 4 8 7 3 2 5 7 7 7 8 9 ...

Page 21: ... 125439 01 Right Stacked 50 Red 1 125451 01 Right Herringbone 50 Red 1 6 124214 01 Left Stacked 36 Red 1 124226 01 Left Herringbone 36 Red 1 125417 01 Left Stacked 42 Red 1 125429 01 Left Herringbone 42 Red 1 124441 01 Left Stacked 50 Red 1 125453 01 Left Herringbone 50 Red 1 7 124134 01 Side Retainer 36 UM Series 4 124134 02 Side Retainer 42 50 UM Series 4 124134 04 Side Retainer 36 Stainless QM ...

Page 22: ... Rear Herringbone 50 Ivory 1 5 124212 02 Right Stacked 36 Ivory 1 124224 02 Right Herringbone 36 Ivory 1 125415 02 Right Stacked 42 Ivory 1 125427 02 Right Herringbone 42 Ivory 1 125439 02 Right Stacked 50 Ivory 1 125451 02 Right Herringbone 50 Ivory 1 6 124214 02 Left Stacked 36 Ivory 1 124226 02 Left Herringbone 36 Ivory 1 125417 02 Left Stacked 42 Ivory 1 125429 02 Left Herringbone 42 Ivory 1 1...

Page 23: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Page 24: ...is product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded ...

Reviews: