www.fmiproducts.com
116226-01N
24
PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure
34, page 23).
2. Open propane/LP supply tank valve for
propane/LP fireplace or main gas valve
located on or near gas meter for natural
gas fireplace.
3. Make sure control knob of fireplace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas valve (see Figure 35 or
Figure 36, page 23). Apply noncorrosive
leak detection fluid to all joints. Bubbles
forming show a leak. Correct all leaks at
once.
5. Light fireplace (see
Operation
, page 27).
Check all other internal joints for leaks.
6. Turn off fireplace (see
To Turn Off Gas to
Appliance
, page 28).
INSTALLING OPTIONAL WALL
MOUNT SWITCH - GWMS2
1. Connect one terminal of 25 ft. wire for
wall switch to TPTH terminal on valve.
Connect remaining wire terminal to TH
terminal on valve. Make sure that wire ter
-
minals are in positions on unit as pictured
in Figure 37. If wires are not connected as
shown switch will not work.
2. Route 25 ft. wire through openings pro
-
vided on sides of burner system to a con
-
venient location to mount your switch.
3. Connect one bare wire end to each termi
-
nal of GWMS2 wall switch.
4. Install wall switch and cover in the wall.
FIREPLACE INSTALLATION
Continued
Figure 37 - Connecting Wall Switch to
Control Valve
To Wall
Switch
Accessory
Figure 38 - Control Valve Terminals
To Optional
Remote
Accessory
To Wall
Thermostat
INSTALLING OPTIONAL WIRELESS
HAND-HELD REMOTE CONTROL
TRC AND MRC SERIES
NOTICE: Use only alkaline bat
-
teries (not included).
Installing Remote Receiver
1. Open bottom louver (V)(KC36 series) or
remove screen door assembly (V)(KCC36
series) and locate switch bracket on the
right.
2. Remote receiver can be placed in the
hole on the switch bracket or place on the
floor underneath the firebox. See remote
instructions for further information.
3. Attach terminal wires to battery.
4. Connect wires from receiver to TH and
TPTH to control valve (see Figure 38).