background image

www.desatech.com 

123679-01B

3

Gas Fireplace Installation

1.  Fireplace  should  be  fully  assembled.  See 

Assembling 

Fireplace

 in fireplace owner’s manual.

2.  Place mantel base close to installation location. See fire

-

place owner’s manual for installation clearances. Leave 

enough room to insert fireplace from back of mantel.

3.  Install gas line. See 

Connecting to Gas Supply

 in fireplace 

owner’s manual. Remember to leave access to the gas 

shutoff valve somewhere on the base or where it is ac

-

cessible to the user.

4.  Check for leaks. See 

Checking Gas Connections

 in fire

-

place owner’s manual.

5.  Position  fireplace  inside  mantel  (see  Figure  4).  Care

-

fully position gas lines. 

IMPORTANT

: Use caution when 

positioning fireplace on base. Base may scratch easily. 

Make sure fireplace is in proper position within mantel 

opening before continuing with installation.

6. 

Fireplace with louver door:

 Lower bottom louver door. 

Use two screws provided in hardware package and attach 

fireplace to wooden base. Close louver door.

 

Fireplace  with  fixed  louver:

  Before  installing  logs  or 

burner assembly (see owner’s manual) remove screws 

securing floor to assembly. Lift floor for access to bot

-

tom of fireplace. Use two screws provided in fireplace 

hardware package and attach fireplace base to wooden 

base. Reinstall floor with screws removed previously.

7.  Carefully  push  mantel  and  base  into  position  against 

wall.

Electric Fireplace Installation

This mantel can be used with DESA Heating, LLC electric 

fireplaces. Electric fireplaces install from the front of mantel. 

To install electric fireplace see fireplace instruction manual. 

Figure 4 - Installing Gas Fireplace

Reviews: