If you wish to install an unvented (vent-free)
gas log set, only unvented gas log sets which
have been found to comply with the standard
for unvented room heaters, ANSI Z21.11.2 are
to be installed in this fireplace.
WARNING: If the fireplace
has been used for wood burning,
the firebox and chimney must be
cleaned of soot, creosote and
ashes be a qualified chimney
cleaner. Creosote will ignite if
heavily heated.
WARNING: When using a
decorative vented gas log, the
damper must be removed or
permanently locked in the fully
open position and the glass doors
must be in the fully open position.
OPTIONAL GAS LINE INSTALLATION
Continued
PUREFIRE HOOD INSTALLATION
1. The PureFire hood supplied with this fire
-
place is packaged in a separate box and
placed in the firebox during shipping.
2. Remove hood from box. Locate brackets
(quantity 2) and screws (quantity 4) for
hood installation in the hardware bag.
3. Using screws provided, secure the bracket
to the inner dome of the fireplace as shown
in Figure 27. The left and right bracket are
different. The edge that is straight will be
closer to the fireplace opening.
4. Lift hood up into the fireplace and place it
on the retaining brackets (Figure 27). The
rear of the hood will touching the rear of
the fireplace.
Figure 27 - Installing PureFire Hood