This firebox may be installed in an after market* manufactured (mobile) home, where not prohibited by state or 
local codes. 

 

Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer (i.e. Installation of this product is permitted after the manufactured  (mobile) home is 
sited).    

 

Save this manual for future reference.  

UNVENTED (VENT-FREE) 
   UNIVERSAL FIREBOX 

   INSTALLATION INSTRUCTIONS 

D1115 

Model FGPN 

36” Peninsula Heat-Circulating Firebox 

 
 
 
 
 
 

Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance. 

 

WHAT TO DO IF YOU SMELL GAS: 

• 

Do not try to light any appliance. 

• 

Do not touch any electrical switch; do not use any
phone in your building. 

• 

Immediately call your  gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions. 

• 

 If  you cannot reach your  gas supplier,  call the
fire department.   

Installation and service must be performed by  a
qualified installer, service or the gas supplier.    

WARNING: If the information in this manual is
not followed exactly, a fire or explosion may result
causing a property damage, personal injury or
loss of life. 

WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or property
damage. Refer to this manual for correct
installation and operational procedures. For
assistance or additional information consult
a qualified installer , service agency or the
gas supplier.       

WARNING: For use only with decorative
type unvented room heaters.  Do not build a
wood fire.  

This firebox has been tested and approved
by I.A.S. under their REQ. 2-97 for use with
any ANS Z21.11.2 approved gas logs. 

Summary of Contents for FGPN

Page 1: ...ly call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a...

Page 2: ...n hot for a time after shutdown Allow surfaces to cool before touching 13 Carefully supervise young children when they are in the same room with the firebox 14 Turn the firebox off and let cool before...

Page 3: ...d without the blower the firebox requires no electricity making it ideal for emergency back up heat BLOWER ACCESSORY The firebox will accept the CBKUVPN accessory The variable blower allows you to sel...

Page 4: ...fy your space provide adequate ventilation Unusually Tight Construction The air that leaks around door and windows may provide enough fresh air for combustion and ventilation However in buildings of u...

Page 5: ...Total 79 000 Btu Hr Do not include the direct vent gas appliances Direct Vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with...

Page 6: ...ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor Con...

Page 7: ...the floor is 0 inches E Clearances from the open end of the firebox to the facing wall should not be less than 36 inches Minimum clearances to combustible are Back of outer casing 0 min Drywall to sid...

Page 8: ...rances shown in Figure 7 Follow the instructions below to install the firebox in this manner 1 Frame in rough opening The firebox framing should be constructed of 2 x 4 lumber or heavier Construct fra...

Page 9: ...rebox combustible materials such as wall board gypsum board sheet rock drywall plywood etc may be butted up next to the side and top of the firebox Combustible materials should never overlap the fireb...

Page 10: ...coming NPT black iron gas line You may also route the eincoming NPT black iron gas line directly to the appliance regulator Remove the gas line cover plate from the vent free firebox s outer surround...

Page 11: ...ing provided see Figure 15 The receptacle may be relocated to either side when necessary However the cover plate must be replaced over the unused access point Be certain to properly ground the vent fr...

Page 12: ...erly 5 Apply gentle force between hook and loop mounting strips to seat blower 6 Remove control knob and lock nut from blower speed control shaft 7 Place the speed control shaft through 3 8 hole provi...

Page 13: ...alter the setting on the pilot assembly See the operating instructions supplied with your vent free log heater for additional cleaning instructions IMPORTANT Turn off the gas supply at the external s...

Page 14: ...rn the defective part to the factory PART NOT UNDER WARRANTY Contact authorized dealer of this product If they can t supply original replacement part s call Fireplace Manufacturer s Part Department at...

Page 15: ...t circulation and may be be installed during or after firebox installation POLISHED BRASS HOOD FGA6017 For End 02240 FGA6054 For Sides 02239 Replaces the standard black hoods to provide a more formal...

Page 16: ...15 ILLUSTRATED PARTS BREAKDOWN Model FGPN UNVENTED VENT FREE FIREBOX...

Page 17: ...de Refractory Retainer 2 9 12125 Screen 4 10 26752 Louver Assy Black 2 11 26733 Lower Door Panel 2 12 14200 Receptacle 1 13 21171 Access Hole Cover 3 14 12126 Screen 1 15 26771 Louver Assy End 1 16 11...

Page 18: ...BURNING CONVENTIONAL FIREPLACE FUELS SUCH AS WOOD COAL OR ANY OTHER SOLID FUEL WILL CAUSE DAMAGE TO THE GAS APPLIANCE WILL PRODUCE EXCESSIVE TEMPERATURES AND WILL RESULT IN A FIRE HAZARD LIMITATION OF...