VENTING INSTALLATION

NOTICE: Do not seal termination 

cap to vent pipe. Cap must be 

removable  for  vent  inspection 

and maintenance.

INSTALLATION PRECAUTIONS

•  Wear  gloves  and  safety  glasses  for 

protection

•  Use extreme caution when using ladders 

or when on roof tops

•  Be aware of electrical wiring locations in 

walls and ceilings

The following actions will void the warranty 

on your venting system:

•  Installation  of  any  damaged  venting 

component

•  Unauthorized  modification  of  the  venting 

system (Do not cut or alter vent components)

•  Installation  of  any  component  part  not 

manufactured or approved by FMI 

PRODUCTS, LLC

•  Installation  other  than  as  instructed  by 

these instructions

 

WARNING: This gas fireplace 

and  vent  assembly  must  be 

vented  directly  to  the  outside. 

The venting system must NEVER 

be attached to a chimney serv

-

ing a separate solid fuel burning 

appliance. Each direct vent gas 

appliance must use a separate 

vent system. Do not use com

-

mon vent systems.

 

WARNING:  Vent  pipe  air 

space  clearances  to  combus

-

tibles are 1" on all sides except 

on the horizontal sections, 

which  require  2"  clearances 

from the top of the pipe. Where 

the termination cap penetrates 

a combustible wall, 1" air space 

clearance is required.

NOTICE: Read these instruc-

tions completely before attempt

-

ing installation.

These models are tested and approved for 

use with FMI PRODUCTS, LLC (direct vent) 

pipe components and terminations.
The venting system must terminate on the 

outside of the structure and can not be at-

tached to a chimney or flue system serving a 

separate solid fuel or gas burning appliance. 

A direct vent appliance must have its own 

venting system. DO NOT common vent this 

appliance.
These models are approved to be vented 

either horizontally through an outside wall or 

vertically through a roof or chase enclosure 

using the following guidelines:

•  When venting system terminates horizon

-

tally on an outside wall, you may install 

a standoff if the termination cap is to be 

installed  directly  on  a  combustible  finish 

such as vinyl, wood, stucco, etc.

•  Never run the vent downward as this may 

cause excessive temperatures which could 

cause a fire.

•  Vent  pipe  air  space  clearances  to  com

-

bustibles are 1" on all sides except on the 

horizontal sections, which requires 2" clear-

ance from the top of the pipe. Where the 

termination cap penetrates a combustible 

wall, 1" air space clearance is required.

•  Have fireplace and selected vent compo

-

nents on hand to help determine the exact 

measurements when elbowing or offsetting. 

Always use wall firestops when penetrating 

walls and firestops when penetrating ceil

-

ings or attic spaces.

•  For installation of fireplace at elevations of 

4000 feet or greater, pay special attention 

to venting requirement recommendations.

 WARNING: Read all instruc-

tions completely and thoroughly 

before  attempting  installation. 

Failure to do so could result in 

serious injury, property damage 

or loss of life.

NOTICE: Failure to follow these 

instructions will void the warranty.

Summary of Contents for EADV36NE

Page 1: ...nce Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup...

Page 2: ...ation of Termination Cap 9 Requirements for the Commonwealth of Massachusetts 10 Venting Installation 11 Fireplace Installation 19 Operation 24 Gas Control Module System 25 Inspecting Burners 26 Clean...

Page 3: ...or other flammable material on or near the appliance Never place any objects on the appliance Do not use this fireplace to cook food or burn paper or other flam mable material This fireplace reaches...

Page 4: ...eplace SAFETY Continued 6 Have venting system inspected annually by a qualified service person If needed have venting system cleaned or repaired See Cleaning and Maintenance page 26 7 Do not use any s...

Page 5: ...ither vertical or horizontal applications This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed Each time you turn on your...

Page 6: ...n back sides or top of your fireplace except where standoff spacers are integrally attached If standoff spacers are attached to your fireplace these spacers can be placed directly against wall or fram...

Page 7: ...stallation All minimum clearances must be met If you are using a separate combustible man tel piece refer to Figure 5 for proper instal lation height You can install noncombustible mantels at any heig...

Page 8: ...ireplace Dimensions 21 1 8 36 25 1 8 42 29 36 34 3 4 42 12 36 13 3 4 42 4 1 2 41 36 48 42 20 1 2 36 24 42 44 36 48 42 38 7 8 36 43 3 4 42 1 1 2 35 36 42 42 43 36 50 42 1 1 33 36 37 42 3 1 4 11 36 11 1...

Page 9: ...n US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally...

Page 10: ...ctly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEE...

Page 11: ...pe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burning appli...

Page 12: ...gs indentations These lugs will slide straight into match ing slots on male ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sect...

Page 13: ...Siding standoff must sit flush against exterior fascia material 6 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting horizontal run to vent cap see Figu...

Page 14: ...ation Configurations Figures 14 and 15 page 15 show a configu ration for venting with horizontal termination with a chart of critical minimum and maximum dimensions which MUST be met If using a ventin...

Page 15: ...lbow Wall Firestop H 90 Elbow V 90 Elbow Horizontal High Wind Square Termination 76 Min 42 73 Min 36 1 Pipe Min On Horizontal Run V Vertical Minimum Required Vertical Pipe H Horizontal Maximum 33 2 ft...

Page 16: ...e 45 elbows instead of 90 elbows The 45 elbow offers less restriction to the flow of flue gases 5 Place flashing over pipe section s extending through roof Secure base of flashing to roof and framing...

Page 17: ...n Double Wall Pipe Galvanized P58 48 48 Section Double Wall Pipe Galvanized PA58 712 Adjustable 7 12 Section Double Wall Pipe Galvanized E58 45 45 Elbow Galvanized E58 90 90 Elbow Galvanized HTS 58 Ho...

Page 18: ...ATION Continued Figure 18 Vertical Venting Configuration Vertical Venting V 40 max Figure 19 Vertical Venting Configuration Using Two 90 Elbows Venting with Two 90 Elbows Vertical V1 Horizontal H 6 mi...

Page 19: ...nt shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the equipment shutoff valve from your retailer For propane LP connection only the installer must supply...

Page 20: ...in Figure 21 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and fireplace Locate sediment trap drip leg where trapped matter is not li...

Page 21: ...luid to all joints Bubbles forming show a leak Correct all leaks at once 5 Reconnect fireplace and equipment shutoff valve to gas supply Check recon nected fittings for leaks Test Pressures Equal To o...

Page 22: ...26 Removing Replacing Door Removing Glass Door If replacement of glass is necessary the entire frame assembly must be replaced Gloves must be worn when removing replacing glass door If glass is broke...

Page 23: ...an open flame to check for a leak Apply noncorrosive leak de tection fluid to joints Bubbles forming show a leak Correct leaks at once CAUTION The gas supply shall be shut off prior to discon necting...

Page 24: ...1 2 Turn off all electric power to fireplace 3 Turn safety shutoff switch to the OFF position Figure 29 Turning Equipment Shutoff Valve to the OFF Position Equipment Shutoff Valve 4 Remove face trim p...

Page 25: ...wing posi tive and negative directions 4 Replace battery cover onto remote control unit CONTINUOUS PILOT FEATURE This allows the change from a spark to pilot system to a standing pilot system 1 There...

Page 26: ...CK UP This fireplace is equipped with a battery back up If the power was to go out on the fireplace the battery back up allows the fireplace to remain operational Make sure to periodically check the c...

Page 27: ...ac CAUTION Do not vacuum if pieces are hot Use only glass door replacement intended for this fireplace see Replacement Parts page 37 for detail on ordering No substitutions may be made See Removing Re...

Page 28: ...ve is not opening 7 No power to unit or ignition module REMEDY 1 Check to see if you have gas supply and that equip ment shutoff valve is opened 2 Repeat lighting procedure several times to purge all...

Page 29: ...rm the pilot is spark ing and lights Check the two plastic connectors that plug in the face of the gas control valve Confirm the gas control valve is properly grounded to the module 1 Check electrical...

Page 30: ...efective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Debris around burner air mixer 2 Improper vent configuration OBSERVED PROBLEM Gas odor even...

Page 31: ...imum Inlet Supply Pressure 11 w c Maximum Inlet Supply Pressure 13 w c Orifice 50 WIRING DIAGRAM AUX Green Orange White Valve Black Red Control Module Black Brown Brown Red Black AC Power Adapter To R...

Page 32: ...www fmiproducts com 125996 01C 32 PARTS MODELS V EADV36NE V EADV36PE AND V EADV42NE 1 2 6 6 7 15 3 9 10 5 8 11 4 3 12 13 14...

Page 33: ...125856 02 Burner Assembly 36 Propane LP 1 126010 01 Burner Assembly 42 NG 1 5 126028 01 Plenum Assembly 36 1 126028 02 Plenum Assembly 42 1 6 122652 01 Door Latch 2 7 121431 01 Gasket 36 1 111913 02...

Page 34: ...www fmiproducts com 125996 01C 34 PARTS MODELS V EADV36NE V EADV36PE AND V EADV42NE 11 3 6 4 5 1 7 9 15 8 13 12 14 23 16 17 18 19 20 21 22 22 2 9 10...

Page 35: ...ifice 27 NG 1 7 14296 Brass Elbow 1 8 11214 Bulkhead Fitting 1 9 116573 01 Flat Washer 6 10 14399 Brass Elbow 2 11 114027 01 Grommet 12 125063 01 Gas Valve NG 1 125063 02 Gas Valve LP 1 13 125064 01 C...

Page 36: ...lain 42 1 2 125860 01P Panel Left Porcelain 36 1 125862 01P Panel Left Porcelain 42 1 3 125860 02P Panel Right Porcelain 36 1 125862 02P Panel Right Porcelain 42 1 PARTS MODELS V EADV36NE V EADV36PE A...

Page 37: ...lling have ready your name your address model and serial numbers of your fireplace how fireplace was malfunctioning purchase date Usually we will ask you to return the part to the factory SERVICE HINT...

Page 38: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____...

Page 39: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____...

Page 40: ...C who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material laborandincidentalcostsas...

Reviews: