126452-01
Rev. A
10/12
2701 S. Harbor Blvd.
Santa Ana, CA 92704
1-866-328-4537
www.fmiproducts.com
CAUTION: Always handle fiber panels with two hands.
Do not force fiber panels into place. Excessive force will
break fiber panels.
Figure 3 - Installing Rear Brick Panel
Figure 2 - Removing Log Base Assembly from Fireplace
Rear Brick
Panel
Rear Screw
Front Two Screws
4. Place the side panel behind the floor panel retainer. Slide front
side of the panel behind the retaining edge of the fireplace.
Gently press the panel back against the side wall (see figure
4). The bottom edge of the panel will rest on the floor and
against the back panel.
5. Secure side panel to side wall of fireplace with one retainer
bracket and two screws (see Figure 5).
6. Repeat steps 4 and 5 to install other side of firebrick panel.
7. Put log base assembly back into fireplace. Secure log base
assembly with the three screws removed in step 2 (see Figure
2).
Figure 4 - Installing Side Brick Panel
Figure 5 Securing Side Brick Panel
Side Wall
Retainer Bracket
Retaining
Edge
Floor Panel
Retainer
Side Panel
Screws
WARNING: Test all gas piping and connections for
leaks after installing or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a
leak. Apply non corrosive leak detection fluid to all joints.
Bubbles forming show a leak. Correct all leaks at once.
8. Replace logs. Make sure logs are put in their proper position.
See Installing Logs in the Fireplace Owner ʼs Manual.
9. Replace screen (see Figure 1, page 1).