www.desatech.com
115425-01E
8
INSTALLATION
Continued
Figure 6 - Checking Gas Joints
Gas Meter
Equipment.
Shutoff.Valve
HEARTH KIT ASSEMBLY AND
INSTALLATION
Kit Assembly - Ramp Pan Burner
1. Determine which side gas line feeds into
fireplace. This log set is factory set up for
right.side.(facing).gas.feed..If.your.gas.line.
is on the right side, go to
Installation and
Gas Connection
..If.your.gas.line.is.on.the.
left side of fireplace, proceed with steps 2
through 4 below.
2.. Remove.nuts.securing.gas.inlet.venturi.to.
bottom.of.burner.
3.. Remove.venturi.from.pan.taking.care.not.to.
damage gasket between venturi and pan.
4.. Reverse.direction.of.venturi.and.reattach.
to.bottom.of.pan.using.factory.nuts.
Figure 7 - Venturi Gas Connection
Burner Orifice
(Factory.Installed)
Burner.Inlet.Venturi.
(Attached.to.Pan.
Bottom)
Gas Connector
Tube
Adapter.
Fitting
Burner.Inlet.Fitting.
(Factory.Installed)
Installation and Gas Connection
1.. Place. ramp. burner. assembly. in. center.
of fireplace floor. Make sure front of pan
faces forward.
2. Thread gas supply fitting to fireplace gas
supply.pipe..Use.thread.sealant.
3.. Install.gas.connector.tube.to.gas.supply.
fitting. Carefully shape tube to attach to
adapter fitting. Be careful not to cause
kinks.in.tube.
4.. Attach.opposite.end.of.gas.connector.tube.
to gas inlet fitting on end of venturi.
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1.. Close.equipment.shutoff.valve.(see.Fig-
ure.5).
2. Pressurize supply piping system by either
using.compressed.air.or.opening.main.gas.
valve.located.on.or.near.gas.meter.
3. Check all joints from gas meter to equip
-
ment.shutoff.valve.(see.Figure.6)..Apply.
noncorrosive leak detection fluid to gas
joints. Bubbles forming show a leak.
4.. Correct.all.leaks.at.once.
TESTING BURNER FOR LEAKS
1. Generously apply noncorrosive leak
detection fluid to all connections.
WARNING: Never check for
gas leaks with open flame.
2. Light burner with shutoff valve no more
than. half. open. and. holding. a. match.
slightly. in. front. of. pan. (see.
Lighting In-
structions
, page 10).
3. Inspect all connections for bubbles, raw
gas odor, or flame from any area other than
burner (leaks). If leaks are detected, shut
off gas valve immediately. Tighten, or reas
-
semble loose connection(s) using pipe joint
compound.until.burner.system.is.leak.free.
4. When burner is tested and leak free, ob
-
serve individual tongues of flame on burner.
Make.sure.all.ports.are.clear.and.producing.
flame evenly across burner. If any ports
appear blocked, clear by removing burner
manifold and reaming ports with a modified
paper.clip.or.other.suitable.tool.
5. When finished testing, turn gas shutoff
valve OFF to extinguish all flames.
Figure 5 - Equipment Shutoff Valve
Open
Closed
Equipment.
Shutoff.
Valve