background image

Summary of Contents for Baja II

Page 1: ... fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA hood must be installed when using a vent free gas log heater see Accessories p 10 WARNING ALWAYS LEAVE GLASS DOORS FULLY OPENED OR FULLY CLOSED WHEN OPERATING THIS FIREPLACE SQUARE CHASE TOP ROUND TOP TERMINAnON TERMINATI...

Page 2: ...STALLATION PG 4 7 8 FAN KIT ASSEMBLY CHIMNEY PIPE INSTALLATION PG 4 PG 4 5 6 9 TERMINATIONS 10 FINISHING YOUR FIREPLACE 11 MANTELS PG 6 PG 7 PG 7 12 GLASS DOORS PG 7 13 GAS LINE INSTALLATIONS PG 8 14 CHIMNEY OFFSET PG 9 15 DAMPER OPERATION PG lO 16 TECHNICAL SERVICE 7 REPLACEMENT PARTS AND ACCESORIES _ PG I0 PG ll For moreinformation visitWWHJ desaJech com ...

Page 3: ... as a FACTORY BUILT FIREPLACE SELECTING LOCATION To determine the safest and most efficient location for the fireplace you must take into consideration the following guidelines 1 The location must allow for proper clearances see figures 1 2 2 Consider a location where the fireplace would not be affected by drafts air conditioning ducts windows or doors 3 A location that avoids the cutting ofjoists...

Page 4: ...material having a thermal conductivity of K 0 84 BTU IN FT HR F or less at I thick For example if the material selected has a K factor of 0 25 such as glass fiber the following formula would apply 0 25 0 84 x 1 0 0 30 thickness required Thermal conductivity K of materials can be obtained from the manufacturer or supplier of the non combustible material If the hearth extension is to be covered use ...

Page 5: ...S I IEASURED TO THE nur GAS OUTL T HEIGHT 0 Figure 8 WALL CHIMNEY SYSTEM Each double wall chimney section consists of a galvanized outer pipe a stainless steel inner flue pipe and a wire spacer The pipe sections must be assembled independently as the chimney is installed When starting chimney directly to the fireplace the inner flue pipe section must be installed first with the lanced side up The ...

Page 6: ... OR STAPLES MIN OF B Figure 12 PENETRATING THE ROOF To maintain a I inch clearance to the pipe on a roof with a pitch a rectangular opening must be cut STEP 1 Determine the center point through which the pipe will penetrate the roof STEP 2 Determine the center point of the roof Pitch is the distance the floor drops over a given span usually 12 inches A 6 12 pitch means that the roof drops 6 inches...

Page 7: ...n instructions supplied with the termination The terminations approved for this fireplace are the RT 8DM and RTL 8DM 8DM El L 8DM and ETLO 8DM for chase style termination only Figure 16 shows an RTL 8DM round top termination RTL BDM ATTACH BRACKET 111111f TABS TO OUTER PIPE 3 PLACES FLUE GAS OUTl ET SECURE WITH OF TER INAnON CAP SCREWS FLUE PIPE OF _ RTL 8D INSIDE INNER PIPE OF CHI NEV CAULK Figur...

Page 8: ...in figure 20 TOP VIEW OF FIREPlACE EXAMPLE 1 EXAMPLE 2 NO MATCO j FAC Rb L F EBOX FIREPLACE I BOTH SIDES j I Figure 20 VI I I I 9 5 8 L 8 15 16 8 1 4 LI 7 9116 L 6 7 8 6 3 16 5 1 2 t3 I 4 13 16 4 118 3 7 16 2 3 4 2 1 16 1 3 8 1t 16 2 3 4 5 6 7 8 9 10 It 12 13 14 INCHES MiDimum 14 iochcsfrom perpendicular side aU MINIMUM SIDE CLEARANCE Example 1 figure 20 The face of a mantel bookshelf etc is made ...

Page 9: ... gas line conduit sleeve Save insulation for reuse STEP 3 Run a liz inch black iron gas line into the fireplace through the gas line conduit sleeve Provide sufficient gas line into fireplace chamber for fitting connection see figure 23 NOTE Secure incoming gas line to wood framing to provide rigidity for threaded end SIDE FIREBRICK FINISHED SIDE GAS LINE PROVIDE ENOUGH CONDUIT THREADED END FOR FIT...

Page 10: ...ach in and push the handle back into the keyhole slot then pull down and forward to lock it in place see figure 24 0751 0750 Figure 24 D1J09 ALTER lAl E INSTALLATIONS WARNING Risk of fire Replace grate with DESA model 107001 01 grate only This grate has been designed to keep the operation ofyour fireplace safe and efficient FOR FURTHER OPERATlNG GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLE...