FAN KIT ASSEMBLY: VCBK3E  

A Fan Kit is optional

 

(for Models W36C & IW36C only) with 

this fireplace.  Use of blowers or fans other than manufactured 
by DESA voids the warranty. Fan is operated by simply 
pressing the rocker switch in the lower right corner of the 
fireplace face (see figure 6). 

NOTE:

  Fireplace must be wired to the house electrical 

system in order for fan to operate.  This fan system does not 
require a wall switch.   
Electrical connections are made through the cover on the side 
of the fireplace illustrated in Figure 7.  Use 14 AWG copper 
wire for all connections.  Be certain the fireplace is properly 
grounded. 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
CHIMNEY PIPE 

The DESA chimney system consists of 12, 18, 24, 36 and 48 
inch, snap-lock double-wall pipe segments, planned for 
maximum adaptability to individual site requirements.  Actual 
lengths gained after fitting overlaps must be taken into 
consideration (lineal gain) and are given in the following 
chart: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ASSEMBLING AND INSTALLING THE DOUBLE 
WALL CHIMNEY SYSTEM 
 

Each double wall chimney section consists of a galvanized 
outer pipe, a stainless steel inner flue pipe and a wire spacer.  
The pipe sections must be assembled independently as the 
chimney is installed.  When starting chimney directly to the 
fireplace, the inner flue pipe section must be installed first 
with the lanced side up.  The outer pipe section can then be 
installed over the flue pipe section with the hemmed end up. 
Press down on each pipe section until the lances securely 
engage the hem on the fireplace starter.  The wire will assure 
the proper spacing between the inner and outer pipe sections. 

 
Continue to assemble chimney sections as outlined above, 
making sure that both the inner and outer pipe sections are 
locked together.

   

When installing double wall “snap lock” 

chimney together, it is important to assure the joint between 
the chimney sections is locked. Check by pulling chimney 
upward after locking. The chimney will not come apart if 
properly locked.  It is not necessary to add screws to keep the 
chimney together (Exception – see page 5 figure 10). 
 

INSTRUCTIONS WHEN ELBOW OFFSET OF 
CHIMNEY IS NEEDED: (30E-8DM) 

 
TO INSTALL ELBOWS 
 
1.

 

To achieve desired offset, you may install combinations 
of 12”, 18”, 24”, 36” and 48” length of double wall pipe 
(SEE SINGLE OFFSET CHART, FIGURE 9 & 11). 

 

 OFFSET CHART (22-50 FT. SYSTEM HEIGHT) 

 

 

 
 
 
 
 
 
Figure 7 

 
 
 
 
 
 
 
 
 
 
 
Figure 6 

OFF

ON

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 8 

OFFSET

RISE

A

B

48"

36"

24"

18"

12"

4 - 3/8

16 -3/8

9 - 3/4

25 - 1/2

1

12 - 3/4

30 - 3/4

1

15

34 - 3/4

1

18

40

1

1

21 - 1/4

46 - 1/4

1

23 - 3/4

49 - 1/4

1

1

27 - 3/4

56 - 3/4

1

30

60 - 3/4

1

1

33

66 1

1

36

71

1

1

38 - 1/4

75

2

41 - 1/4

80 - 1/4

1

1

1

45

86 - 3/4

2

46 - 3/4

89 - 1/2

1

1

1

51

97

1

1

53 - 1/4

101

2

1

56 - 1/4

106 - 1/4

2

59 - 1/4

111 - 1/2

1

1

1

61 - 3/4

115 - 1/2

2

1

64 - 3/4

120 - 3/4

2

1

68 - 1/4

127

1

2

70

130

2

1

1

74 - 1/4

137 - 1/2

1

2

1

76 - 3/4

141 - 1/2

1

2

1

79 - 3/4

146 - 3/4

4

ELBOW SET ONLY

CHIMNEY LENGTH

WARNING: 

The opening in the collar around the 

chimney at the top of the fireplace must not be obstructed. 
Never use blown insulation to fill the chimney enclosure. 

Summary of Contents for Baja II 36WIL

Page 1: ...pproved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA hood must be installed when using a vent free gas log heater see Accessories p 10 WARNING ALWAYS LEAVE GLASS DOORS FULLY OPENED OR FULLY CLOSED WHEN OPERATING THIS FIREPLACE SAVE THIS BOOK This book is valuable In addition to instructing you on how to install and m...

Page 2: ...5 HEARTH EXTENSION PG 3 6 OUTSIDE AIR KIT INSTALLATION PG 4 7 FAN KIT ASSEMBLY PG 4 8 CHIMNEY PIPE INSTALLATION PG 4 5 6 9 TERMINATIONS PG 6 10 FINISHING YOUR FIREPLACE PG 7 11 MANTELS PG 7 12 GLASS DOORS PG 7 13 GAS LINE INSTALLATIONS PG 8 14 CHIMNEY OFFSET PG 9 15 DAMPER OPERATION PG 10 16 TECHNICAL SERVICE PG 10 17 REPLACEMENT PARTS AND ACCESORIES PG 11 ...

Page 3: ...arances see page 7 Finishing your Fireplace Chimney Outer Pipe Surfaces 1 Min WARNING DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS MINIMUM MAXIMUM CHIMNEY HEIGHT The MINIMUM height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 11 5 feet for straight flue or a flue with one elbow set The maximum distance between elbows is 2...

Page 4: ...r of non combustible inorganic material having a thermal conductivity of K 0 84 BTU IN FT HR F or less at 1 thick For example if the material selected has a K factor of 0 25 such as glass fiber the following formula would apply 0 25 0 84 x 1 0 0 30 thickness required Thermal conductivity K of materials can be obtained from the manufacturer or supplier of the non combustible material If the hearth ...

Page 5: ... flue pipe section with the hemmed end up Press down on each pipe section until the lances securely engage the hem on the fireplace starter The wire will assure the proper spacing between the inner and outer pipe sections Continue to assemble chimney sections as outlined above making sure that both the inner and outer pipe sections are locked together When installing double wall snap lock chimney ...

Page 6: ...hich the pipe will penetrate the roof STEP 2 Determine the center point of the roof Pitch is the distance the floor drops over a given span usually 12 inches A 6 12 pitch means that the roof drops 6 inches for each 12 inches one measure horizontally down the roof STEP 3 Use the roof opening chart figure 13 below to determine the correct opening length and flashing required STEP 4 Remove the shingl...

Page 7: ... any case refer to the installation instructions supplied with the termination The terminations approved for this fireplace are the RT 8DM and RTL 8DM that can be used for flashing or chase and ET 8DM ETO 8DM ETL 8DM and ETLO 8DM for chase style termination only Figure 16 shows an RTL 8DM round top termination Terminations with 16 slip pipe sections are available The RTT 8DM and RTTL 8DM are appro...

Page 8: ... the fireplace The clearances from the side of the fireplace to any combustible material and wall should fall within the limits shown in figure 20 Example 1 figure 20 The face of a mantel bookshelf etc is made of combustible materials and protrudes 2 from the wall the fireplace is installed in This combustible material must be a minimum of 4 from the side of the fireplace opening Example 2 figure ...

Page 9: ... gas line to wood framing to provide rigidity for threaded end STEP 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired The gas pipe is intended for connection to an unvented vent free or a decorative gas appliance vented g...

Page 10: ...to lock it in place see figure 24 FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER TO YOUR HOMEOWNERS GUIDE OR CONTACT YOUR AUTHORIZED DEALER TECHNICAL SERVICE You may have further questions about installation operations or troubleshooting If so contact The Technical Service Department at 1 888 427 8322 When calling have the model number of the fireplace ready Fi...

Page 11: ...For more information visit www desatech com 10 REPLACEMENT PARTS ACCESSORY PARTS ...

Reviews: