3.8.4 IO interface
Menu 4.3.7
contains the diagnostic functions for the IO interface (8 outputs, 2 inputs). It gives a
view of the current statuses of the inputs and outputs of the external interface module.
This menu item can be actuated only when the connection to the IO interface is active.
Diagnosis IO-Interface Menu 4.3.7
The eight
outputs
can be
switched by pressing the corre-
sponding number
(1-8)
. In the
case of outputs allocated to a
hose path in the configuration
of the IO interface, this is pos-
sible only when the electronic
seal is broken.
The diagnostic function can be used only when the connection to the IO inter-
face is active.
On exiting the diagnostic screen, the IO interface is re-initialised according to the
specified configuration.
It is essential that the functions of each output are noted.
IO-Interface
Outputs
Inputs
Status
System message
Outp. 1 2 3 4
0
0
0
0
Outp. 5 6 7 8
0
0
0
0
--------------------
Input 1 2
0
0
Testing ...
IO online
IO Test-Start
--- --- ---