Sening
®
Innovative Tank Truck Systems
EPE2-Controller for Meter Draining System
EPE2
Installation Manual
MN F08 003 US /
DOK-450E
Rev. 1.03 / JS / jp / March 2010
25
3.8.3 EPE2
The following description is relevant only for program versions from 5.00
(approval according to MID).
The connection to the EPE2 is interrupted during the data transfer between the MultiFlow
and the chip card and is automatically restored at the end.
The EPE2 diagnostic functions are compiled in
menu 4.3.6
.
Diagnosis EPE2 Menü 4.3.6
The EPE2 is connected to the MultiFlow’s external CAN bus. A connection to the EPE2 via
the CAN bus is required in order to control the EPE2. This connection can be made for test
purposes using key
<1>
and/or broken using key
<3>
.
The EPE2 has one output. The status of this output can be changed during the test using
key
<2>
. The EPE2 also has one further input.
Actual statuses (connection, input and output) are shown in the central section of the display.
EPE2
Control options
Current status
1 2 3
Link Output Link
ON change OFF
Link Output Input
1 0 H
Testing ...
Link. Start Broken