![FMC Technologies INVALCO 49016811 Installation & Operation Manual Download Page 14](http://html.mh-extra.com/html/fmc-technologies/invalco-49016811/invalco-49016811_installation-and-operation-manual_2312626014.webp)
14
Issue/Rev. 0.6 (2/06)
Introduction
The Model 4200 Rate/Totalizer is designed to accept fre-
quency or pulse inputs from a wide range of flowmeters and
to display flowrate and a re-settable total directly in engineer-
ing units. Scaled pulse output is standard. The Model 4200
is fully programmable with K-Factors, linearization of multiple
K-Factors, decimal point positions, and timebase being pro-
grammed via the front panel switches. The instrument is
housed in a durable weatherproof polycarbonate enclosure
that can be mounted directly on a flowmeter, panel mounted
or wall mounted using a pivoting bracket.
Quick Setup
The steps below are to be used only if you do not require
pulse or analog output.
1. Press and hold the [Program] to enter the programming
mode.
2. Press [Program] to skip “Linear”.
3. In “Factor” mode.
a.
Press [+] to increase number.
b.
Press [-] to decrease number.
4. Press [Enter/Next] to move cursor left, press [K
Factor] to move cursor right.
5. Repeat steps 4 and 5 until entire K Factor is entered.
6. Press [Program] once to show F.dEc (Flow Rate Deci-
mal Point) mode.
a.
Press [+] to increase number.
b.
Press [-] to decrease number.
7. Press [Program] once to show t.dEc (Total Decimal
Point).
a.
Press [+] to increase number.
b.
Press [-] to decrease number.
8. Press [Program] once to show tScale (Time Scale)
mode.
a.
Press [+] or [-] to change time scale shown.
b.
Sec = rate per second
c.
60 Sec = rate per minute
d.
Per hr = rate per hour
e.
24 hr = rate per day.
9. Press [Program] once to “SPULSE” mode.
10. Press [Program] once to “ANALOG” mode.
11. Press [Program] once to “PASS” mode.
12. Press [Program] once to “ACCEPT” mode.
13. Press [Enter/Next] to exit programming mode.
Specifications
Display
Continuously powered LCD
Total
6 digits, 0.5” (12.7mm) high, resettable from the front panel
Rate
6 digits, 0.5” (12.7mm) high
Resolution
16 bits (0.05% of span)
Accuracy
.01% of Total, +/- 1 count
K-Factor
Programmable, pulses per unit of measure, .001 to
999.999
Timebase
Rate displayed in units per second, minute, hour or day
Frequency Range
0.00 Hz to 4250 Hz
Input Signal
Sine wave (20mV P/P min), Pulse, Reed Switch, others
Operating Temperature
-40°F to 158°F (-40°C to 70°C)
Mounting
Meter mount or panel/wall mount
Enclosure
Weatherproof and corrosion resistant
Battery Operated Version
Approvals
Intrinsically safe to Class 1, Div. 1 Grp A,B,C&D; CUL/UL
pending
Battery Type
3.6 volt Lithium Battery pack
Battery Life
5 years typical (Without utilizing the Scaled Pulse Output)
Activating pulse out requires additional processing resources
that will increase battery drain and shorten battery life.
Connection
Two wire connection to probe
Output Type
Open drain transistor to ground (Resistive closure to
ground)
Model Number Designation
Field Mounted Base Unit
4200 - x0
4200 - x1
Mounting Options
1x
3x
Battery (Lithium) Powered Version - Pulse Output
Loop Powered Version w/4-20mA Rate Output
Standard Weatherproof Wall Mount/Panel Mount
Standard Weatherproof Swivel Meter Mount Stem 1” FNPT