This Focus Meter will measure camera signals from all types of analog cameras and is most useful when 

used on the HD type analog cameras like HD-TVI, HD-CVI, and AHD cameras. The BNC type connectors are 
used to input the HD and CVBS (base-band composite) video signals.  It can also be used to input YPbPr, and 
RGB signals by connecting to the "Y" or “G” channel that has the sync signal on it. Only the channel that has 
the sync signal on it should to be connected for proper operation. The RGB signal format is measured using one 
of the three channels, the Chroma/Sync channel normally the "G" or Green with Sync or any channel can be 
measured as long as it has the synchronization signal on it.    
 
 

DISPLAY FORMAT: 

 

 

When the HDFM-1 meter measures and displays the following formats. 

 

              HDTV   

 

 

   EDTV 

 

 

 

 SDTV 

 

1080i       (SMPTE 274M) 

480p  (ITU-R BT.1358)  

NTSC (SMPTE 170M) 

1080p      (SMPTE 274M)  

576p  (ITU-R BT.1358)  

PAL     (ITU-R BT.470) 

1080PsF  (SMPTE RP 211)   

 

   480i 

 

 

(SMPTE 

267M) 

720p        (SMPTE 296M)        576i 

 

 

(ITU-R 

BT.601) 

 

* 1080PsF  

is a Progressive Segmented Frame video signal  and reads as 1080i

See the note on last page. 

 

 
DISPLAY FOCUS:

 

 
 

When the unit is in Focus mode the display will react to changes in the camera focus both numerically and 

on the bar graph display. The meter is measuring information in the scene and will react to changes in the focus 
ring and also changes in the image or content of information in the scene. If you have set the maximum focus on 
the camera and you put your hand up in front of the camera you will see the numbers and bar graph go down in 
focus. This is caused by the loss of information caused by the change of (in focus) information. When focusing the 
camera be sure to stay outside of the image of the camera when setting maximum focus. 

 

 
CARE AND MAINTENANCE: 
 

No routine maintenance or test procedures are required other than battery replacement. Attempts at field 

repair or adjustment will void the warranty.

 

 

 

The HDFM-1 is a precision measuring instrument and should be treated accordingly. While it can withstand 

ordinary every day indoor use, it should not be left outside in the rain or otherwise mistreated. It is not waterproof. 
The battery should be removed if it is placed into storage to prevent leakage of corrosive fluids from batteries as 
they discharge and age.  

  

 

Replace batteries at least once a year even if ordinary use does not discharge the battery because old 

batteries may leak and cause corrosion damage. If the HDFM-1 fails to operate even after battery replacement, or 
does not read a known video signal correctly, call the factory for a Return Authorization Number and return it to the 
factory for repair. 
 

HDFM-1isb 

 

 

 

 

 

 

 

 

 

 

 

PAGE 4 OF 5 

Summary of Contents for HDFM-1

Page 1: ...HDFM 1 HIGH DEFINITION CAMERA FOCUS METER INSTRUCTION MANUAL IB 647701 ALL RIGHTS RESERVED ...

Page 2: ...HDFM 1 TABLE OF CONTENTS DESCRIPTION METER OPERATION INPUT SIGNALS AND CONNECTORS DISPLAY FORMAT DISPLAY FOCUS CARE AND MAINTENANCE BATTERIES ENCLOSURE AUXILIARY EQUIPMENT HDFM 1isb PAGE 1 OF 5 ...

Page 3: ... format and Lines of definition of the video signal and briefly displays that information on the LCD display then it goes into focus mode so you can set the maximum focus on the camera The ability to measure the video format and lines of definition can help you identify and verify any unfamiliar camera you come across in your work With the multi format cameras and DVRs available today it is easy t...

Page 4: ...splay for fine tuning of the focus ring on the camera If there is movement in the scene you will see a small amount of change in the display this is caused by the information in the display changing and so the focus number will change slightly If the meter is being used with video un terminated you may see this display appear asking you to terminate the video input If you see this display put a 75...

Page 5: ... meter is measuring information in the scene and will react to changes in the focus ring and also changes in the image or content of information in the scene If you have set the maximum focus on the camera and you put your hand up in front of the camera you will see the numbers and bar graph go down in focus This is caused by the loss of information caused by the change of in focus information Whe...

Page 6: ... rating of 94 5VA The meter comes with an impact resistant rubber boot to protect it during daily use AUXILIARY EQUIPMENT The MC1 MC2 and MC3 are Protective Carry Cases to house and protect the HDFM 1 and your other test meters while being transported These are very rugged water resistant ABS cases with foam lined interiors suitable for transporting this meter and other test equipment You can orde...

Reviews: