background image

OPERATION (cont.)

 

 
1. 

 

White level is automatically gain-regulated to make the white  

 

level (luminance) exactly 100 I.R.E. White level is not clipped  

 

but retains a linear gray scale. Level is adjusted up as well as 

 

down to keep the luminance level correct. Output video level is  

 

regulated to 1 volt peak-to-peak. 

 
2. 

Chrominance (color information) is automatically corrected, thus  

 

compensating for cable slope losses up to 5000 feet and other 

 

sources of high frequency attenuation. 

 
3. 

Back Porch Clamping eliminates all incoming low frequency  

 

interference such as 60 cycle ground loops, and also cancels low 

 

frequency distortion in the video signal. Common Mode interference 

 

is also eliminated. 
 
 

Since ACE472 automatically processes sync and picture peak 

voltages  independently without altering the time relationships 
within the video signal, the timing between SYNC and COLOR BURST is 
not altered. Therefore horizontal Sync, Color Burst Timing, and 
Chrominance Phase (SC/H) retain their original relationship. This 
feature distinguishes the ACE472 from any Proc Amp that strips and 
re-inserts new SYNC signals. 

 
 

 

The ACE472 insures constant standard video signals even  though 

video from a multitude of variable level sources are  

used.  

This 

 

helps to insure correct CCTV operation without loss of signal 

 

due to over or under video level and improves overall picture 

 quality. 
 

FRONT PANEL INDICATORS

 

 
 

A "VIDEO ON" indicator for each channel shows that a video signal 

is present at that input to identify signal continuity. 

 

  

BY-PASS PUSH BUTTON OPERATION

  

 
 

The ACE472 has a by-pass mode of operation. The switch on the front 

panel is used to set the amplifier and equalizer to unity gain, (no 
correction). With this push button you can make a quick comparison 
between active control and no control. Use this button to see the 
picture improvement gained by the ACE472. Look at the video image and 
push the button, compare the before and after picture quality. 
 
 

Depressing the by-pass button also enables the operator to examine 

the picture without automatic correction, so that the action of the 
camera iris controls may be observed, and if necessary, be adjusted. 
 
 

CARE AND MAINTENANCE OF THE ACE472 
 
 

Care should be taken not to subject the ACE472 to   extreme       

moisture or temperatures outside normal operating   range.  There  are  no 
periodic maintenance adjustments to be   made on the ACE472. If the unit 
does not function properly it  should  be  returned  to  the  factory  for 
repair. There are no field adjustable controls. 
 