background image

Assembly Instructions

Shaft Assembly (A)
1. Locate the lower shaft (A1) into the upper shaft

(A2).

2. Grasp firmly and hold steady the lower shaft.  Lo-

cate the upper shaft and snap together firmly.

The unit is correctly assembled when the gap be-
tween the upper and lower shaft has been closed.

Safety Guard Assembly (B) & (C)
1. Locate the safety guard (B1) over the cutting

head (B2).  Ensure the nylon line is fed through
the hole in the safety guard as illustrated in fig B.

2. Push into location and turn safety guard in the di-

rection illustrated in Fig C, until a click is heard
and the safety guard is securely locked in posi-
tion.

ENSURE THE SAFETY GUARD IS SECURELY
IN PLACE BY ATTEMPTING TO TWIST GUARD.

A

1

2

Starting and Stopping

1

2

B

C

WARNING
Cutting head continues to rotate after the trimmer has
been switched off.

To start your trimmer
1. Squeeze the safety lock-off lever/switch lever (D).

To stop your trimmer
1. Release the switch lever.

2

1

Cables

IMPORTANT
If you want to use an extension cable when operating your
product, only the following cable dimensions should be used:
- 1.0 mm 

2

: max length 40m

- 1.5 mm 

: max length 60m

- 2.5 mm 

2

: max length 100m

Minimum rating:
1.00mm

2

size cable, 10 amps 250 volts AC.

YOUR PRODUCT IS SUPPLIED WITH AN ELECTRIC
MAINS CABLE WIRED DIRECTLY INTO THE PRODUCT.
1. If the supply cord is damaged, it must be replaced

by your local Husqvarna UK Ltd. Approved Service
Centre or similarly qualified persons in order to avoid
a hazard.

2.Flymo Extension Cables are available from your 

local Husqvarna UK Ltd. Approved Service Centre. 

3.Do not wire an extension cable directly to your product

yourself.  Please contact your local Husqvarna UK Ltd.
Approved Service Centre for further information on the
connectors and kits available.

4.Only use extension cables specifically designed for

outdoor use and which conform to one of the following
specifications: Ordinary rubber (60245 IEC 53), Ordinary
PVC (60227 IEC 53) or Ordinary PCP (60245 IEC 57)

CONNECTORS
Our connectors are suitable for use with 2 core cable
only.  Under no circumstances should these connectors
be used for earthed products.
All of our connectors and cables are of splashproof con-
struction.  They are not waterproof and must not be left
outside permanently nor should they be submerged or im-
mersed in water.  Do not let cable lay or trail through pools of
water or splashed with water from hose pipes.

MAINS PLUG REPLACEMENT

If the plug supplied is cut off it should be destroyed.
There is an electric shock hazard if a cut off plug is in-
serted into a 13 amp socket.

1. No earth required. Our products are double insulated

to EN60335 and under no circumstances should an
earth be connected to any part of the product.

2. Ensure the mains voltage suits your product.
3. IMPORTANT!
The wires in the mains lead are coloured in accordance
with the following code:
BLUE  -  NEUTRAL           BROWN  -  LIVE
The wire which is coloured BLUE must be connected to
the Terminal which is marked with the letter ‘N’ or
coloured BLACK.  The wire which is coloured BROWN
must be connected to the Terminal which is marked with
the letter ‘L’ or coloured RED.
4. It is important that the outer sheath is clamped cor-

rectly into the 3-pin plug.

5. If in doubt consult your local Service Repairer or quali-

fied electrician before the machine is used.

6. A 13 Amp fuse must be fitted to the Mains Plug.
7. The normal plug fuse and household fuse only protect

the electrical equipment and are not a safeguard
against electrocution.

If your product is hard wired i.e. non-detachable
mains electric cable, a conversion kit and exten-
sion cable is available from all Husqvarna Outdoor
Products Approved Service Centres which can be
found in your local Yellow Pages.

D

Summary of Contents for STXT25

Page 1: ... Original Instructions IMPORTANT INFORMATION Read before use retain for future reference Speedi Trim ...

Page 2: ...on of Symbols on the product Warning Read the user instructions carefully to make sure you understand all the controls and what they do Keep others including children pets and bystanders outside the 10 metre hazard zone Stop the trimmer immediately if you are approached Wear eye protection To avoid the possibility of electric shock do not use in damp or wet conditions Switch off Remove plug from m...

Page 3: ...oiding kinking 12 Use only on AC mains supply voltage shown on the product rating label 13 Our trimmers are double insulated to EN60335 Under no circumstance should an earth be con nected to any part of the trimmer Preparation 1 While using your product always wear eye protec tion substantial footwear and long trousers Do not operate the equipment when barefoot or wearing open sandals 2 Before usi...

Page 4: ...ble 4 Only use extension cables specifically designed for outdoor use and which conform to one of the following specifications Ordinary rubber 60245 IEC 53 Ordinary PVC 60227 IEC 53 or Ordinary PCP 60245 IEC 57 CONNECTORS Our connectors are suitable for use with 2 core cable only Under no circumstances should these connectors be used for earthed products All of our connectors and cables are of spl...

Page 5: ... trimmer around trees H and near plants E G F H 1 Automatic Line Feed System Line cutter J How the automatic line feed works J 1 When initially switching on the trimmer a small length of line is fed out 2 A clattering noise will be heard when the nylon line hits the line cutter DO NOT BE ALARMED this is quite normal After approximately 5 seconds the line will be cut to the correct length and the n...

Page 6: ...h are available from Husqvarna UK Ltd stockists To fit spool and line complete 1 Remove old spool 2 Place new spool into spoolholder with cut out areas of the spool in line with eyelets as shown in figure M 3 Release one line from cleat and feed line through eyelet M 4 Repeat for second line Ensure spool is fully located by gently rotating it during fitment whilst keeping the spoolholder steady 5 ...

Page 7: ... Centre or Husqvarna UK Ltd Customer Service Is the line cutter missing from the safety guard Contact Husqvarna UK Ltd Customer Service Telephone 0844 844 4558 UK 1800 882 350 ROI No No No Yes Yes LINE NOT FEEDING OR LINE TOO SHORT OR TRIMMER VIBRATES CONTINUOUS CLATTERING NOISE LINE SNAPS CONTINUOUSLY IF NONE OF THE ABOVE OR IF FAULT PERSISTS Has the motor reached full speed before use No Allow t...

Page 8: ...varna UK Ltd or by the ma chine having been modified in any way Guarantee Guarantee Policy Service Recommendations Your product is uniquely identified by a silver and black product rating label We strongly recommend that your product is serviced at least every twelve months more often in a professional application EC Declaration of Conformity Husqvarna AB S 561 82 Huskvarna Sweden Declare under ou...

Reviews: