background image

Cables

IMPORTANT
Use only 1.00mm

2

size cable up to 40 metres

length maximum.
Maximum rating:
1.00mm

2

size cable, 10 amps 250 volts AC.

YOUR TRIMMER IS SUPPLIED WITH AN
ELECTRIC MAINS CABLE WIRED DIRECTLY
INTO THE PRODUCT.

1. Mains Cables and Extension Cables are avail-

able from your local Approved Service Centre.

2. Do not wire an extension cable directly to your

product yourself.  Please contact your local Ap-
proved Service Centre for further information on
the connectors and kits available.

3. Only use extension cables specifically de-

signed for outdoor use.

4. If the supply cable is damaged, it must be re-

placed by the manufacturer, its service agent
or similarly qualified persons in order to avoid
a hazard.

CONNECTORS
Our connectors are suitable for use with 2 core
cable only.  Under no circumstances should these
connectors be used for earthed products.
All of our connectors and cables are of splash-
proof construction.  They are not waterproof and
must not be left outside permanently nor should
they be submerged or immersed in water.  Do not
let cable lay or trail through pools of water or
splashed with water from hose pipes.
MAINS PLUG REPLACEMENT

If the plug supplied is cut off it should be de-
stroyed.  There is an electric shock hazard if a
cut off plug is inserted into a 13 amp socket.

1. No earth required.  Our products are double in-

sulated to EN60335 and under no circum-
stances should an earth be connected to any
part of the product.

2. Ensure the mains voltage suits your product.
3. IMPORTANT!
The wires in the mains lead are coloured in accor-
dance with the following code:
BLUE -

NEUTRAL

BROWN

-

LIVE

The wire which is coloured BLUE must be con-
nected to the Terminal which is marked with the
letter ‘N’ or coloured BLACK.  The wire which is
coloured BROWN must be connected to the Ter-
minal which is marked with the letter ‘L’ or
coloured RED.
4. It is important that the outer sheath is clamped

correctly into the 3-pin plug.

5. If in doubt consult your local Service Repairer

or qualified electrician before the machine is
used.

6. A 13 Amp fuse must be fitted to the Mains

Plug.

7. The normal plug fuse and household fuse only

protect the electrical equipment and are not a
safeguard against electrocution.

If your product is hard wired i.e. non-detach-
able mains electric cable, a conversion kit and
extension cable is available from all Approved
Service Centres which can be found in your
local Yellow  Pages.

Summary of Contents for Mini Trim 2009

Page 1: ...IMPORTANT INFORMATION Read before use retain for future reference Original Instructions ...

Page 2: ...oduct Warning Read the user instructions carefully to make sure you understand all the con trols and what they do Keep others including children pets and bystanders outside the 10 metre hazard zone Stop the trimmer immedi ately if you are approached The use of eye protection is recom mended to protect against objects thrown by the cutting line To avoid the possibility of electric shock do not use ...

Page 3: ...carefully avoiding kinking 12 Use only on AC mains supply voltage shown on the product rating label 13 Our trimmers are double insulated to EN60335 Under no circumstance should an earth be con nected to any part of the trimmer Preparation 1 While using your product always wear substan tial footwear and long trousers 2 Before using the machine and after any impact check for signs of wear or damage ...

Page 4: ...with water from hose pipes MAINS PLUG REPLACEMENT If the plug supplied is cut off it should be de stroyed There is an electric shock hazard if a cut off plug is inserted into a 13 amp socket 1 No earth required Our products are double in sulated to EN60335 and under no circum stances should an earth be connected to any part of the product 2 Ensure the mains voltage suits your product 3 IMPORTANT T...

Page 5: ... fed through the hole in the safety guard as illustrated in fig B 2 Push into location and turn safety guard in the direction illustrated in Fig C until a click is heard and the safety guard is securely locked in position ENSURE THE SAFETY GUARD IS SE CURELY IN PLACE BY ATTEMPTING TO TWIST GUARD Cable Restraint D1 D2 1 Form loop in mains cable and push the loop through the slot as illustrated in p...

Page 6: ...sing the tip F 2 Swing trimmer in and out of the cutting area taking small cuts F F Line cutter G Manual Line Feed System To feed the nylon line 1 Press and hold the two latches G 2 Gently pull the line until it reaches the line cut ter 3 Release the two latches Check that the spool is locked in position 4 If too much line has been fed out press the two latches and turn the spool anti clockwise un...

Page 7: ...e line from cleat Unwind approximately 100mm of line and feed through slot in spool holder J 3 Re fit spool into spoolholder Check that the spool is locked in position To replace nylon line on spool 1 Take approximately 5 metres of line and insert into one of the line lock holes in the spool K 2 Wind line onto spool in the direction of the ar rows on the top of the spool Care should be taken to en...

Page 8: ...eached full speed before use No Allow the motor to reach full speed before use Are you using the trimmer correctly Only use tip of nylon line to trim Is the line jamming on the spool Yes Rewind the line on the spool if symptoms still persist change spool and line Replacement Parts Spool and Line Reference no FLY031 Part no 513106090 Maintenance After you have finished using your trimmer follow the...

Page 9: ...n not authorised by Husqvarna UK Ltd f The machine has not been used for hire g The machine is owned by the original purchaser h The machine has not been used commercially This guarantee is additional to and in no way diminishes the customers statutory rights Failures due to the following are not covered therefore it is important that you read the instructions contained in this Operator s Manual a...

Page 10: ... in the table The maximum hand arm vibration weighted value measured according to EN ISO 5349 on a sample of the above product s corresponds to the Value ah given in the table 2000 14 EC The Measured Sound Power LWA Guaranteed Sound Power LWA values are according to the tabulated figures Conformity Assessment Procedure Annex VI Notified Body Intertek Cleeve Road Leatherhead Surrey KT22 7SB England...

Reviews: