4.4.3 VSI Submenu
Back:
confirm to go back to previous menu.
Exit:
confirm to go directly to the main screen.
Filter:
increase the number if the reading is affected by
noise on the input signal, decrease the value if the reading
is delayed related to the input signal.
Default = 10
Min = 1 (faster)
Max = 100 (slower)
The unit of measure will be chosen automatically according
to the unit of measure chosen in the altimeter and will be
“ft/min” if “ft” has been chosen or “mt/sec” if “mt” has been
chosen.