FLYBOX
Omnia57-80 ALTI-VARIO
-
Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 2.0
®
22
Instrument settings
4.4.2 Altimeter Submenu
Qnh Unit:
set the pressure reference for the Altimeter unit
between hecto Pascal (hPa) or Inches of Mercury (inHg).
Back:
confirm to go back to
previous menu.
Exit:
confirm to go directly to
the main screen.
Unit:
set the unit of
measure of the Altimeter in
Feet (ft) or Meters (mt). The
chosen unit will affect the
VSI unit as well.
Altimeter range
Min
Max
ft
0
26000
m
0
8000
Filter:
increase the number if the reading is affected by
noise on the input signal, decrease the value if the reading
is delayed related to the input signal.
Default = 10, Min = 1 (faster), Max = 100 (slower)
Press range
Min
Max
hPa
950
1050
inHg
28,05
31