ECLIPSE
–
USER MANUAL ____ VER. 1.3 ENG
©
Copyright
FLY
Products
s.r.l.
PAGE 21
SETTING #
2
:
THE TORQUE
A very important setting concerns the contrast
to the torque generated by the rotation of the propeller which can be:
◙
ANTI-CLOCKWISE in engines with BELT reduction such as
MOSTER
◙
CLOCKWISE in engines with MECHANICAL reduction such as the
ATOM 80
To counter the torque produced by the propeller rotation,
the position of the support
D
is,
To the
RIGHT
of the pilot on the
MOSTER
,
to the
LEFT
of the pilot on the
ATOM
.
For size
XS
(extra small)
or to lift the seat
you can move backwards
the front support "
B
"
with the possibility of
raise further
the cricket "
C
"
of 1 hole up.