background image

3

The products referred to in this manual conform to the European Community Directives to which
they are subject:
Low Voltage 2014/35/EU
Electromagnetic Compatibility 2014/30/EU

Protection against explosion
The protection screen, lens or uv screen on the lamp can be damaged to the degree of failure 
if visible damage, such as a crack or deep mark, should be replaced

Lamp

The maximun temperature that can be reached on the external surface of the fitting,
in a thermally steady state,is 120

℃。

120℃

Never look directly into the light source. You risk injury to your retina, which may induce blindness.

Do not look at LEDs with magnifiers, telescopes, binoculars or similar optical instruments that may 
concentrate the light output.

Protection optical radiation

Before starting any maintenance work or cleaning the projector, cut off power from the mains supply.
After switching off, do not remove any parts of the fitting, to avoid getting burnt for at least 30 minutes. 
After this time the likelihood of the lamp exploding is virtually nill.
The fitting is designed to hold in any splinters produced by a lamp exploding. 
The lenses must be mounted and, if visibly Damaged, they have to be replaced with genuine spares.

When the luminaire projects an object, the minimum distance of the luminaire to 
the flammable object is 12 meters

.

The fitting mounts a high-pressure lamp that needs an external .
Immediately replace the lamp if damaged or deformed by heat.
The light source in this fixture shall be replaced by the manufacturer or its service agent or 
similar qualification.
Always disconnect from mains before replacing the lamp.

Summary of Contents for LIGHT SKY F1700WB

Page 1: ...F1700WB Please read these user manual carefully before use E mail n Address No 43 Yunfeng Road Xiuquan Street Huadu District Guangzhou China...

Page 2: ...y to ensure excellent performance and best meet your expectations and requirements Carefully read this user manual in its entirety and keep it safe for future reference It is essential to know the inf...

Page 3: ...the fixture creating a potential fire hazard Mounting surface and fire protection Keep all combustible materials at least 20 cm away from the fixture This lighting fixture is for professional use onl...

Page 4: ...te the light output Protection optical radiation Before starting any maintenance work or cleaning the projector cut off power from the mains supply After switching off do not remove any parts of the f...

Page 5: ...ade via USB interface Display Menu The display panel adopts a 2 8 inch color LCD screen which is used in both Chinese and English languages to facilitate quick operation and browse menus Display board...

Page 6: ...5 1 CTO Color wheel 5 Magenta 4 Orange A11 A36 CTB DL058 SPF044 A06 7 Congo A23 2 Green A05 A08 8 Red 1 Blue White 6 CTB 3 1 2minus green 2...

Page 7: ...2800 3048 18100 1682 8830 820 4850 451 2970 276 1770 164 720 67 420 39 205 19 130 12 112 10 10 15 20 40 Distance m 45 diameter m ft in 4 diameter m ft in 0 0 8 2 7 7 6 24 11 1 3 4 3 12 4 40 8 1 7 5 7...

Page 8: ...ATTACHMENT AND BODY SIZE 7...

Page 9: ...must be securely fixed to the support structure of the projector and then connected to the base handle 8 Make sure all parts for fixing the projector are in a good state of repair Make sure the point...

Page 10: ...ral operate press the power switch to check whether every thing is working normally connection to the eiectricty mains must be carried out by a qualified electrical installer or L N black blue brown y...

Page 11: ...3 or 5 pin XLR pug and socket If need to lengthen the communication cable please make sure the both side of 3 or 5 pin plug is one to one one to one two to two three to three Otherwise the communicati...

Page 12: ...nter OK function Exit in the choice screen DMX 001 DMX Address Information Personal Manual control Service Language Reversal UP DOWN LEFT RIGHT ENTER Press the switch The projector starts resetting th...

Page 13: ...Lamp fan 4 Framing fan Power fan Fan voltage Head fan 1 Head fan 2 Lamp fan 1 Lamp fan 2 Lamp fan 3 Lamp fan 4 Framing fan Power fan RDM info UID 0x3888XXXXXXXX Manufactory Device Label DMX live 1 Pa...

Page 14: ...ule VX XXX Framing module VX XXX Zoom module VX XXX FanDrv VX XXX Ballast info Input voltage XXXV Output voltage XXXV Input current XXXA Output Power XXXW Internal T XXX External T XXX Running state E...

Page 15: ...6 Framing Rot 0 255 17 Framing Mac 0 255 18 Framing Mac Z 0 255 19 Zoom 0 255 20 Focus 0 255 21 Focus fine 0 255 22 Auto Fin 0 255 23 Auto Dis 0 255 24 Frost1 0 255 25 Frost2 0 255 Lamp Switch OFF ON...

Page 16: ...5 Focus 0 255 Frost 1 0 255 Frost 2 0 255 Factory Factory Reset Pass word YES NO Reset timers Pass word Reset power on timers Reset lamp timers Reset all timers Developer Pass word Correlate lamp Manu...

Page 17: ...nu menu menu menu V menu Service Factory Update Pass word Simple update Color module Framing module Zoom module FANDRV ALL Whole update Display Pan Tilt Color module Framing module Zoom module FANDRV...

Page 18: ...5 69 POWER MODE 1400W 70 74 POWER MODE 1700W 75 255 Reserved 7 Shutter strobe 0 31 Shutter closed 32 63 Shutter open 32 default 64 95 Strobe effect from slow to fast 96 127 Shutter open 128 143 Openin...

Page 19: ...55 0 100 Focus 21 0 255 0 100 Focus Fine 22 0 255 0 100 Auto Fin 23 Auto Dis 0 9 N0 function 10 19 10M 20 29 15M 30 39 20M 40 49 30M 50 59 40M 60 255 50M 24 0 127 128 159 160 191 192 255 25 0 127 128...

Page 20: ...10 J13 J14 J1 J17 J14 J4 J5 J10 J13 J12 J11 J9 J8 J7 J15 J3 J6 J16 J6 J7 J8 J9 J10 J1 J3 J4 J5 J11 J12 J13 J12 J11 J10 J9 J8 J7 J1 J5 J17 J6 J3 J2 J13 J14 J4 S1 J4 J3 J2 J1 J3 J4 J9 J12 J13 J14 J15 J1...

Page 21: ...20 CLEANING AND MAINTENANCES TROUBESHOOTING...

Page 22: ...one for the same description Please check the reflector parts is dirty Keep them clear Please measure if the power supply is enough Small adjusting is suitable for change height or screw systen till...

Page 23: ...22...

Page 24: ...23...

Reviews: