l
For transferring flammable liquids class AI, AII and B
only use pumps which are approved for ZONE 0.
F 424 S-../..
EC-Type-Examination Certificate
PTB 00 ATEX 4108 X
F 425 S-../..
EC-Type-Examination Certificate
PTB 99 ATEX 4001 X
F 426 S-../..
EC-Type-Examination Certificate
PTB 00 ATEX 4109 X
F 430 S-../..
EC-Type-Examination Certificate
F 430 HC-../..
PTB 00 ATEX 4110 X
l
Only use explosion-proof electric motors which are
approved for ZONE 1 or compressed air motors.
F 410 Ex
Commutator Motor
F 414 Ex
Three-phase Gearmotor
F 416 Ex
Compressed Air Motor
( approval not necessary )
F 416-1 Ex
Compressed Air Motor
( approval not necessary )
F 416-2 Ex
Compressed Air Motor
( approval not necessary )
F 450 Ex
Commutator Motor
F 460 Ex
Commutator Motor
F 460 Ex EL
Commutator Motor
F 460-1 Ex
Commutator Motor
l
Observe EC-Type-Examination Certificate.
l
The pump is not approved for stationary installation.
l
The explosion-proof motor must definitely be
outside the barrel and/or container.
l
Only use electrically conductive hoses
(see TRbF 131 part 2).
l
The installation and operation must comply with the
relevant Health & Safety Regulations. (In the Federal
Republic of Germany these are "TRbF" and also
"BG Chemie").
For use in hazardous locations
13