background image

3.   Attach an O-ring to the intake tube and slide them into the 

intake extension. Then slide the airline tube into strainer, and 

attach them to the intake extension. Attach a discharge cap 

to the top of the intake tube. Make sure the discharge spout 

faces downwards.

   Adjust the length of the tubes to the aquarium’s water level.

4.   Pass the airline tube through the tube holder, and attach an air 

valve.

5.   Insert the guide of the intake tube into the slot of the breeding 

box. Insert partition plates and slit plates.

   Depending on breeding conditions use the appropriate slit 

plates. Little eggs, fries or juvenile shrimps may be pumped out through partition 

plates or slit plate.

   The thick framed slit plate can be used in the upwards/downwards positions. When 

you place larger bars downwards, it 

will decrease clogging.

   Slide the second airline tube (sold 

separately) into the air valve, and 

connect the other end into an 

air pump (sold separately).

6.  Use partition plate if needed.

   Little eggs, fries or juvenile 

shrimps may flow out through 

the gap.

7.   Pour water into the breeding box.

8.  

Place the cover over the 

breeding box and secure with 

the cover clasps.

9.   Make sure all of the parts are set correctly, and then turn the air pump on.

10.  Use the air valve (ill.1) to gradually adjust water flow into the breeding box.

   Juvenile Guppies may pump out through the slit plate if the amount of inflow water is 

too high.

   The amount of inflow will depend on water level in the main aquarium. If water level in 

the main aquarium is too low, not enough water will be pumped into the breeding box. 

Water in the main aquarium should not be lower than 5 cm (2”) of the aquarium rim.

Slot

Tube 

Holder

Airline Tube

Airline Tube

Air Valve

(ill.1)

Discharge Cap

Intake Tube

O-Ring

Intake 

Extension

Airline 

Tube

Strainer

Guide

Summary of Contents for 015561109420

Page 1: ...US Gal 1 9 L VOLUME VOLUME HANG ON HOLDING BREEDING BOX BAC POUR L ISOLEMENT ET POUR LA REPRODUCTION INSTRUCTION MANUAL MODE D EMPLOI MULTI CHAMBER HOLDING BREEDINGBOX MULTI CHAMBER HOLDING BREEDINGB...

Page 2: ...Rallonge du tube d admission 10 O ring Bague d tanch it 11 Strainer Cr pine d admission 12 Cover Clasps Pinces de retenue pour couvercle 13 Slit plate for discharging water 1 thick frame 3 bars Plaque...

Page 3: ...ame must be less than 47 mm 1 PARTS DIAGRAM Refer to the images and confirm all parts are included Operation requires an air pump and a second airline tube sold separately SET UP INSTRUCTIONS Use atta...

Page 4: ...l decrease clogging Slide the second airline tube sold separately into the air valve and connect the other end into an air pump sold separately 6 Use partition plate if needed Little eggs fries or juv...

Page 5: ...rature in the breeding box Provide your full attention to the breeding box during summer and winter months Fish or shrimp in the main aquarium may swim against the output stream and could swim into th...

Page 6: ...MA DES PI CES Consulter les illustrations et s assurer qu il ne manque aucune pi ce Le fonctionnement exige une pompe air et un tube air suppl mentaire vendus s par ment INSTRUCTIONS D ASSEMBLAGE Uti...

Page 7: ...pri e l tape de croissance Les petits ufs les alevins et les jeunes crevettes pourraient tre entra n s en dehors de leur zone par le courant de la pompe Le positionnement des plaquettes peut tre inver...

Page 8: ...cadre de l aquarium NE PAS permettre la reproduction de trop de poissons la fois dans le bac de reproduction cela pourrait entra ner un manque d oxyg ne Si la temp rature de la pi ce diff re norm ment...

Page 9: ...MEN GEBRAUCHSANLEITUNG MANUAL DE INSTRUCCIONES ISOLATIONS ZUCHTBECKEN MIT MEHREREN KAMMERN CAJA PARA CONTENCI N Y CR A MULTI CHAMBER HOLDING BREEDINGBOX MULTI CHAMBER HOLDING BREEDINGBOX 0 5 US Gal 1...

Page 10: ...g 8 Abflusskappe Tap n de descarga 9 Einlassverl ngerung Extensi n de entrada 10 O ring Junta t rica 11 Ansaugkorb Filtro 12 Abdeckungsklammern Ganchos para la tapa 13 Schlitzplatte f r abflie endes W...

Page 11: ...als 47 mm betragen TEILE BERSICHT Beziehen Sie sich auf die Bilder und vergewissern Sie sich dass alle Teile enthalten sind F r den Betrieb werden eine Durchl fterpumpe und ein zweiter Luftschlauch b...

Page 12: ...en Abteiler oder die Schlitzplatte gepumpt werden Die dickrahmige Schlitzplatte kann in der Aufw rts Abw rtsposition verwendet werden Wenn Sie die gr eren St be nach unten legen vermindert dies Versto...

Page 13: ...Zuchtbecken Dies kann zu einem Mangel an Sauerstoff f hren Wenn die Raumtemperatur und die Wassertemperatur stark von einander abweichen kann die Raumtemperatur die Wassertemperatur in dem Zuchtbecke...

Page 14: ...debe ser inferior a 47 mm 1 85 pulg DIAGRAMA DE PIEZAS Consulte las im genes y confirme que todas las piezas est n incluidas Se necesitan una bomba de aire y una segunda manguera de aire se venden por...

Page 15: ...trav s de las placas divisorias o con ranuras Las placas con ranura de armaz n grueso pueden usarse en las posiciones hacia arriba o abajo Si coloca las barras m s grandes hacia abajo disminuir las ob...

Page 16: ...ara cr a Esto podr a provocar una carencia de ox geno Cuando la temperatura ambiente y la del acuario sean extremadamente diferentes es posible que la primera repercuta en la temperatura del agua de l...

Reviews: