LED status
AI1 ... AI6
Sensor fault
Green
Sensor OK
---
Flashing green
---
Sensor OK, impulses are registered
Flashing orange
Sensor fault
Green, flashing orange
Measured value > Threshold for prewarning
Orange
Measured value > Threshold for warning
Red
Measured value > Threshold for alarm
System status
LED status
SYSTEM - Statusanzeige
SYS - SYSTEM-OK Ausgang
Off
No supply
Fault present
Orange
Boot sequence running
---
Green
Operational
No faults
Flashing orange
Standard IP configuration loading
---
Digital input
LED status
DI
Green
Static signal pending
Flashing green
Dynamic signal pending, e.g. rpm signal
Ethernet
LED status
LINK
ACT
Green
Connection to LAN established
Data transfer active
Event recorder
LED status
EVENT
Off
Once the LED is extinguished the event recorder starts up and records signals.
Green
Event for triggering the event recorder detected
Alarm output
LED status
NO1/ COM1
Green
Alarm output set