3-4
Before every measurement, VIBXPERT checks that the sensor and
cables are correctly connected if sensor detection is activated in
the device setup (p. 2-22). In measurements with trigger (phase,
orbit,...) the trigger signal is monitored. If the trigger signal fails
during measurement, the green LED flashes after the measurement.
The measurement must then be repeated.
Continuous measurement (live mode)
In ‘live mode’, the signal is measured and displayed continuously.
This lets you check the signal and the stability of the measurement.
It is not available for time-limited measurements, such as the
coastdown curve and impact test. The live mode is activated in the
Display Setup (see p. 4-17). The actual data collection begins when
you press 'Enter' again.
Alternatively you can activate the live mode by keeping the
'Enter' key pressed when the measurement starts. The actual data
collection begins when you release the 'Enter' key.
Measurement progress is indicated by a bar at the top edge of the
screen. In the live mode, the ‘Live’ symbol appears in the title bar
and the progress bar remains at 0% (see below).
Save result
After completing a measurement, the blue LED lights if no
measurement failures have occurred and no limit value has been
exceeded (P. 2-2).
• Press the MENU key and click on 'Save' (see below).
• Enter a file name (File manager and Text editor see P. 6-2ff).
Measurement - Multimode
Note
Left:
Live mode =
continuous measurement
Right:
Save result
Note
Progress bar
Live mode enabled