18
TS52PRO Test Set
Users Guide
Note
Battery cover screws are retained in the cover
and will not come all the way out of the battery
cover.
2
Use a Phillips screwdriver to loosen only the four
screws attaching the battery door cover to the
back of the test set. Remove the battery door
cover. Do not access or touch the printed circuit
board or other areas of the test set.
3
Remove the old battery and properly discard.
Make sure the terminals cannot short.
4
Insert a new 9 V alkaline battery into the test set.
Do not use a rechargeable battery. When inserting
the battery, observe the proper polarity.
5
Place the battery door cover on the test set and
fasten the four screws securely. Do not over
tighten the screws. The battery door screws should
be torqued to a maximum of 0.904 N-m or 8 in-lb.
bfp04.eps
Figure 4. Battery Replacement
Replacing or Relocating the Belt Clip
The belt clip assembly is field replaceable in the event
of damage or prolonged wear. It also can be relocated
to one of two locations. To order a replacement belt
clip, contact your local Fluke Networks authorized
distributor.
To replace the belt clip assembly:
1
Use a Phillips screwdriver to remove the screw that
secures the belt clip to the test set housing.
2
Remove the old belt clip and replace with a new
one. Secure the belt clip assembly to the test set
housing with the original screw.
bfp05.eps
Figure 5. Belt Clip Replacement
To relocate the belt clip:
1
At the unused belt clip slot, use a Phillips
screwdriver to remove the screw holding the
plastic insert to the case, then remove the plastic
insert.
2
Use a Phillips screwdriver to remove the screw that
secures the belt clip to the test set housing and
remove the belt clip.
-continued-
Battery door
Battery spacer
9V
Battery
Screws
4 places
(Not removable)