Fluke TS52PRO User Manual Download Page 20

16

TS52PRO Test Set

Users Guide

Speaker/LCD/Test Set Timeout

The speaker uses a lot of battery power. The battery 
drains quickly when the speaker is left on continuously. 
To extend battery life, the test set has a timeout 
function that automatically turns off the speaker when 
the test set is on-hook. A timer starts whenever the test 
set is put on-hook. After the timer times-out, the 
speaker is automatically shut off. 

If the test set is used as a handset in Monitor mode and 
if the test set’s receiver has been set to high volume, 
the battery is drained quickly. To avoid this, the test set 
has a timeout function for the high volume state when 
in Monitor mode. After the timeout, the test set reverts 
to low volume. The timeout duration for the high 
volume Monitor receiver is the same as for the speaker.

The speaker timeout duration is program-mable while 
on-hook and 240 minutes (4 hours) while off-hook. The 
off-hook timeout cannot be changed. Remember, the 
longer the selected timeout duration the shorter the 
battery life. 

To change the speaker/ Monitor mode timeout 
duration:

1

Set the Talk/Monitor switch to 

M

.

2

Press the 

STORE/PROG

 key.

3

Press the 

SPKR

 key. 

4

Press a number key to select a timeout duration. 
The test set gives a confirmation tone when the 
entry is accepted. 

LCD Backlight

You can conserve the test set battery life by keeping 
the display backlight off when it is not needed. The 
default state of the backlight is off. To turn on the 
backlight:

1

Set the Talk/Monitor switch to 

M

.

2

Press the 

STORE/PROG

 key.

3

Press the 

 key. The test set gives a confirmation 

tone.

Repeat the steps to turn the backlight off.

DTMF Digit Grabbing

The TS52PRO Test Set allows you to capture DTMF 
(Dual-Tone Multi-Frequency) tones generated on a 
telephone line. This feature is useful when you suspect 
that the customer’s equipment is not generating 
proper DTMF signals. In order to maximize battery life, 
the default state is to turn DTMF Digit Grabbing off. 
Digit Grabbing is deactivated when the display times 
out. To turn it on:

1

Set the Talk/Monitor switch to 

M

.

2

Press the 

STORE/PROG

 key.

3

Press the 

TEST 

key. The test set gives a 

confirmation tone.

Visual ANAC Mode

(For service provider use only, visual ANAC not available 
in all regions)

You can get an ANAC (Automatic Number 
Announcement Circuit) DTMF response by putting the 
test set in visual ANAC mode:

1

Set the Talk/Monitor switch to 

T

.

2

Press the 

STORE/PROG

 key.

3

Press the 

key. The display shows 

ANAC MODE

.

Table 6. Timeout Durations

Key

Speaker/Monitor Mode 

Timeout Duration

 2 minutes (default)

 5 minutes

 10 minutes

 20 minutes

 30 minutes

 40 minutes

Summary of Contents for TS52PRO

Page 1: ...TS 52PRO Test Set PN 3394309 January 2009 Rev 5 5 2018 2009 2018 Fluke Corporation All product names are trademarks of their respective companies Users Guide...

Page 2: ...ion to refund of the purchase price free of charge repair or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain war...

Page 3: ...peaker and Speakerphone Microphone 4 Audio Controls 4 Display and Keypad 6 Operation 10 Talk Monitor Switch 10 Operating the Test Set in Monitor Mode 10 Caller ID 11 Operating the Test Set in Talk Mod...

Page 4: ...ng a Stored Number 15 Hook Flash Duration 15 Make Receive Only Loud Speaker the Default 15 Speaker LCD Test Set Timeout 16 LCD Backlight 16 DTMF Digit Grabbing 16 Visual ANAC Mode 16 Factory Defaults...

Page 5: ...uitry that prevents disruption of digital data services if the test set is unintentionally connected to a data line Registration Registering your product with Fluke Networks gives you access to valuab...

Page 6: ...Safe in Monitor mode Data detection and lockout in Talk mode Data lockout override DTMF digit grabbing High impedance in Monitor mode High voltage protection Last number redial up to 23 digits Visual...

Page 7: ...ded locking clip that assures a secure connection to belt loops and D rings Both forward folding and backwards folding versions of the belt clip may be installed The test set can be hung by the belt c...

Page 8: ...the display shows no bars the battery should be replaced immediately The test set s battery compartment makes battery replacement easy See Replacing the Battery on page 17 for instructions on changin...

Page 9: ...Speakerphone mode pressing the MUTE key will shut off the speakerphone s microphone and will temporarily put the test set into a Receive Only Loud Speaker mode This is a better mode for troubleshootin...

Page 10: ...the section Speaker LCD Test Set Timeout on page 16 for information on setting the timeout SPKR Speaker The SPKR key turns the test set s speaker on and off It functions in both Talk and Monitor mode...

Page 11: ...The factory default flash duration is 600ms however the duration of the flash signal can be varied by the user For configuring the test set to generate a flash duration other than 600ms see Hook Flas...

Page 12: ...ou are working on has normal CO battery voltage or normal loop current If the voltage is below 2 5 V dc there is not enough voltage for the test set to go off hook If the voltage is above 140 V dc thi...

Page 13: ...ne VOL Toggle volume Toggle volume SPKR Toggle speaker Toggle speaker RCL Initiate speed dial storage Initiate speed dial functions OVERRIDE N A Override data lockout LNR N A Dial last number STORE PR...

Page 14: ...udio signals without disrupting conversations or data signaling that may be present Either the handset receiver or the speaker can be used to monitor a line Note Monitor Mode Only You can monitor a li...

Page 15: ...pair Originating a Call 1 Set the Talk Monitor switch to M 2 Clip the test set to Tip and Ring of a subscriber loop 3 Monitor listen to the line to verify that it is idle 4 If not idle disconnect the...

Page 16: ...Practices Always monitor the line for an audible signal before attempting to go off hook to draw dial tone The data detect circuitry on the test set is designed to detect data signals above the human...

Page 17: ...e is present the test set goes off hook To go back on hook unclip the test set s test leads from the line or put the test set into Monitor mode High Voltage Lockout Operation WWarningX If the voltage...

Page 18: ...is automatically muted If a visual response is not available an audible response is given Use one of the other speed dial locations 0 8 if you always want an audible response Putting a Pause in a Sto...

Page 19: ...ly receive audio signals it cannot transmit any audio signals Receive only is preferred when your main concern is to listen to the line and you do not want ambient noise such as caused by a passing ca...

Page 20: ...tion The test set gives a confirmation tone when the entry is accepted LCD Backlight You can conserve the test set battery life by keeping the display backlight off when it is not needed The default s...

Page 21: ...ory default values 1 Set the Talk Monitor switch to M 2 Press the STORE PROG key 3 Press the pound key The test set gives a confirmation tone when the entry is accepted Maintenance WWarningX Disconnec...

Page 22: ...eps Figure 4 Battery Replacement Replacing or Relocating the Belt Clip See Figure 5 The belt clip assembly is field replaceable in the event of damage or prolonged wear It also can be relocated to on...

Page 23: ...all hardware removed Loose or missing hardware could create a hazard for the end user Note Battery cover screws are retained in the cover and will not come all the way out of the battery cover Be car...

Page 24: ...nd washer Figure 8 3 Fasten the black wire lug to the PC board Tip with screw and washer Figure 8 4 Insert the plastic clip over the line cord strain relief at the base of the test set housing Figure...

Page 25: ...ne Cord with Piercing Pin Clips P4480001 Central Office Line Cord with 346A Plug P4480004 Angled Bed of Nails Cord ABN and Piercing Pin Clips P4480009 Angled Bed of Nails Cord ABN with Piercing Pin Cl...

Page 26: ...er programmable default of 600 ms Automatic Speaker Shut Off Duration User programmable default of 2 minutes Battery 9 V alkaline battery Physical Measurement 10 in x 3 75 in x 4 25 in 254 mm x 96 mm...

Reviews: