Fluke ScopeMeter 192C Getting Started Manual Download Page 4

Fluke 19xC-2x5C 

Getting Started 

 

ii

 

Unpacking the Test Tool Kit 

The following items are included in your test tool kit: 

1. ScopeMeter 

Test 

Tool 

2. Battery 

Charger 

3.  10:1 Voltage Probe Set (Red) 
4.  10:1 Voltage Probe Set (Gray) 
5.  Test Lead Set (Red and Black)  
6.  Bus Health Test adapter (2x5C 

only) 

7.  Safety Infor CD ROM 

with complete Users Manual 

8.  Shipment box (basic version 

only) 

The -S versions also include: 
9.  Optically Isolated USB 

Adapter/Cable 

10.  CD ROM with FlukeView

®

  

Software 

11. Hard Case 
 

 

 

4

3

1

2

7

8

11

10

9

5

(2x)

(2x)

(2x)

d

e

(2x)

b

(2x)

a

(2x)

c

6

Fluke 215C/225C

S-version

Figure 1. ScopeMeter Test Tool Kit 

 
 

Summary of Contents for ScopeMeter 192C

Page 1: ...opeMeter Software version 8 00 onwards Getting Started GB Jun 2008 Rev 1 09 2009 2008 2009 Fluke Corporation All rights reserved Printed in the Netherlands All product names are trademarks of their re...

Page 2: ......

Page 3: ...4 Powering Resetting the Test Tool 4 How to Navigate a Menu example 4 Changing the Information Language 5 Adjusting Contrast and Brightness 5 Using the Scope 5 Multimeter 7 Recorder Functions 8 Field...

Page 4: ...age Probe Set Gray 5 Test Lead Set Red and Black 6 Bus Health Test adapter 2x5C only 7 Safety Information CD ROM with complete Users Manual 8 Shipment box basic version only The S versions also includ...

Page 5: ...anada 31 40 2675200 in Europe 1 425 446 5500 from other countries Safety Information Read First The Fluke Models 192C 196C 199C 215C and 225C ScopeMeter test tools hereafter referred to as test tool c...

Page 6: ...l are more commonly available you might consider using these anyhow Warning To avoid electrical shock or fire if a test tool input is connected to more than 42 V peak 30 Vrms or on circuits of more th...

Page 7: ...used in this manual to indicate a measurement in which the test tool input BNC or banana jack is connected to a voltage different from earth ground The isolated input connectors have no exposed metal...

Page 8: ...batteries at least once a year Powering Resetting the Test Tool Turning power on off The test tool powers up in its last setup configuration Resetting the test tool to the factory settings Turn power...

Page 9: ...ay the USER key labels Enable the arrow keys for adjustment Adjust the contrast of the screen Change the backlight brightness Using the Scope Connect the probe s as shown in figure 2 Figure 2 Scope Co...

Page 10: ...A result on B Reading 1 2 is input B result V ac dB measurement function Glitch Detect glitch capture on or off Average waveform averaging on or off Waveform Normal normal waveform display Persistence...

Page 11: ...e Cal calibration of 10 1 100 1 probe Polarity input polarity normal or inverted variable input sensitivity Bandwidth bandwidth full 10 kHz 20 MHz Multimeter Connect the test leads Figure 1 item 5 to...

Page 12: ...mory is full Mode on Ext start Start stop Stop or continue Run recording if triggered via the meter input Ext Run requires one trigger per division in VIEW ALL mode In Trend Plot Reading 1 2 Scope or...

Page 13: ...rning Result on edge of limits Result not OK Setting up the Limits To set up the test limits of the current bus type do the following From the bushealth screen select SETUP LIMITS For RS 485 only high...

Page 14: ...creens Exit the REPLAY mode Zoom Use the zoom function to obtain a more detailed view of a waveform Display the ZOOM key labels Observe that the trace is frozen HOLD appears at the top of the screen Z...

Page 15: ...epending on cursor measurement type Automatic or manual risetime measurement on a single channel Reading 2 is time T frequency 1 T or RMS value Cursor measurements on trace A B or M if A and B are on...

Page 16: ...occur Single Shot the test tool waits for a trigger After receiving a trigger the waveform is displayed and the instrument is set to HOLD Press to arm for a new trigger Noise reject Filter the noise r...

Page 17: ...anged press the arrow keys to select a character press to set default name press to save RECALL open the Recall recall menu RECALL FOR REFERENCE recall a screen as a reference waveform RECALL SETUP re...

Page 18: ...end Plot or Scope Record You can set the automatic power shutdown time to 5 minutes and to 30 minutes or you can disable the automatic power shutdown Disabled Battery refresh Start a battery refresh a...

Reviews: