Fluke 19xC-2x5C
Getting Started
8
Recorder Functions
First, choose a measurement in Scope or Meter mode.
RECORDER
ANALYZE
Show the recorder functions. Select a
recorder function (Scope Trendplot, Scope
Record, or Meter Trendplot), then press
to display the recorder key labels:
Start (
RUN
) or stop (
STOP
) recording.
Show the recorder options.
Reference:
time reference is time of day
(
Time of Day
) or time from start (
From
Start
).
In Scope Record:
Display Glitches:
glitch detection on, or
10 kHz filter on.
Mode:
Single Sweep
: stores samples
until memory is full, then stops.
Mode:
Continuous
: stores samples
continuously; deletes first samples if
memory is full.
Mode:
on Ext. ...
: start (
Start
), stop (
Stop
)
or continue (
Run
) recording if triggered via
the meter input (
Ext.
).
Run
requires one
trigger per division in
VIEW ALL
mode.
In Trend Plot:
Reading 1 (2)...
(
Scope) or
Measurement...
(
Meter) show the measurement function
menu.
VIEW ALL
: see all stored samples.
NORMAL
: see the most recent 9 divisions.
EXIT
: exit the recorder mode.
Fieldbus Measurements (Bushealth)
The Bushealth function is standard available in the
Fluke 215C-225C.
Selecting the Bus Type
ANALYZE
Show the function selection screen. Select
Bushealth
, then press
.
Highlight the required bus type, the press
.
Dots ... behind a bus type indicate
that a submenu will follow on this selection.
The test tool shows the bushealth screen.
Show information on how to connect the test
tool to the bus (
WIRING INFO
).
Show the bus signal eye pattern (waveform).