Certifying Fiber Cabling
Autotest in Far End Source Mode
1
2
Turn on the tester and smart remote and let them sit for
5 minutes. Allow additional time if the modules have
been stored above or below room temperature. For
other sources, warm up according to the manufacturer’s
recommendations.
Turn the rotary switch to SETUP, then select Fiber. Set
the following on the Fiber tabs (press
C
to see other
tabs):
•
Fiber Type: Select the fiber type to be tested.
•
Test Limit: Select the test limit required for the job.
Press
J
More to see other lists of limits.
•
Remote End Setup: Set to Far End Source
•
Bi-directional: Does not apply to Far End Source
mode.
•
Number of Adapters and Number of Splices: Enter
the number of adapters and splices that will be
added to each direction of the fiber path after the
reference is set.
•
Connector Type: Select the connector type used in
the cabling to be tested. Select General if the exact
type is not listed.
•
Test Method: Refers to the number of adapters
represented in the loss results. Select Method B if
you use the reference and test connections shown
in this manual.
See Table 2 on page 12 for details on settings.
-continued-
29