Fluke DSX-CHA-M12-X-S Manual Download Page 3

3

Set the Reference

Before you use the M12 adapters to test and certify links, set the 
reference. Repeat the reference procedure every thirty days at minimum.

To set the reference

Turn on the tester and the remote a minimum of 1 minute before you 
set the reference. 

Note

Set the reference only after the testers are at an ambient 
temperature between 50 °F and 104 °F (10 °C and 40 °C).

Connect the main and remote testers together as shown at the top or 
bottom of Figure 1.

On the home screen, tap 

TOOLS

, then tap 

Set Reference

.

On the 

SET REFERENCE 

screen tap 

TEST

.

GPU89.EPS

Figure 1. Reference Connections

RJ45 permanent 
link adapter*

RJ45 channel 

adapter*

Optional reference artifact

DSX-8000: DSX-CALIBRATION 2G

DSX-5000: DSX-CALIBRATION

* Permanent link and channel adapters are included  

with your DSX-5000 or DSX-8000 kit.

Summary of Contents for DSX-CHA-M12-X-S

Page 1: ...t 100BASE TX networks have 4 position D coded female connectors DSX CHA M12 X adapters for Gigabit Ethernet 10GBASE T have 8 position X coded female connectors DSX Firmware Requirements Your DSX Cable...

Page 2: ...ct Category With reference to the equipment types in the WEEE Directive Annex I this product is classed as category 9 Monitoring and Control Instrumentation product Do not dispose of this product as u...

Page 3: ...rs are at an ambient temperature between 50 F and 104 F 10 C and 40 C 2 Connect the main and remote testers together as shown at the top or bottom of Figure 1 3 On the home screen tap TOOLS then tap S...

Page 4: ...ect type is not in the LAST USED list tap MORE tap Manufacturers tap the correct manufacturer then tap a cable type Shield Test Shows only for shielded cable types To get a FAIL result if the shield i...

Page 5: ...5 U05 EPS Figure 2 Connections for Channel Tests with Two M12 Connectors Switch Channel 90 m maximum 295 ft M12 M12 M12 Variable frequency drive Main and remote testers with M12 adapters PLC...

Page 6: ...and an M12 Connector Channel 90 m maximum 295 ft PLC Switch M12 M12 Variable frequency drive RJ45 cable from switch M12 Main tester with DSX CHA004 channel adapter Remote tester with M12 adapter Chan...

Page 7: ...RJ45 Connectors Switch PLC Channel 90 m maximum 295 ft Variable frequency drive M12 M12 M12 RJ45 cable from switch RJ45 cable from VFD Main and remote testers with DSX CHA004 channel adapters Channel...

Page 8: ...ed cable types To get a FAIL result if the shield is open select On See the Versiv Series Users Manual for more information Test Limit If the correct patch cord limit is not in the LAST USED list tap...

Page 9: ...atest version of firmware is available at no charge on the Fluke Networks website Contact Fluke Networks www flukenetworks com support info flukenetworks com 1 800 283 5853 1 425 446 5500 Fluke Networ...

Page 10: ...behalf To obtain service during the warranty period contact your nearest Fluke Networks authorized service center to obtain return authorization information then send your defective product to that S...

Reviews: