Digital Multimeter
General Specifications
15
Function
Range
Resolution
Accuracy ± ( [ % of Reading ] + [ Counts ] )
AC Volts (Average
responding)
6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
2.0 % + 2
(45 Hz to 1 kHz)
DC mV
600.0 mV
0.1 mV
0.3 % + 1
DC Volts
6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.3 % + 1
Continuity 600
Ω
1
Ω
Meter beeps at <25
Ω
, beeper turns off at >250
Ω
;
detects opens or shorts of 250
μ
s or longer.
Ohms
600.0
Ω
6.000 k
Ω
60.00 k
Ω
600.0 k
Ω
6.000 M
Ω
50.00 M
Ω
0.1
Ω
0.001 k
Ω
0.01 k
Ω
0.1 k
Ω
0.001 M
Ω
0.01 M
Ω
0.5 % + 2
0.5 % + 1
0.5 % + 1
0.5 % + 1
0.5 % + 1
2.0 % + 1
Diode test
2.400 V
0.001 V
1 % + 2
Capacitance
1000 nF
10.00
μ
F
100.0
μ
F
9999
μ
F
[1]
1 nF
0.01
μ
F
0.1
μ
F
1
μ
F
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
AC Amps (Average
responding)
[2]
60.00 mA
400.0 mA
[3]
6.000 A
10.00 A
[4]
0.01 mA
0.1 mA
0.001 A
0.01 A
2.5 % + 2
(45 Hz to 1 kHz)
[1]
In the 9999
μ
F range for measurements to 1000
μ
F, the measurement accuracy is 1.2 % + 2.
[2]
Amps input burden voltage (typical): 400 mA input 2 mV/mA, 10 A input 37 mV/A.
[3]
400.0 mA accuracy specified up to 600 mA overload.
[4]
>10 A unspecified.