Safety Compliance: 

IEC 61010-1 2nd Edition CAT I, 30 V;

 

Pollution Degree 2 

CSA C22.2 No. 1010.1; 
ANSI/ISA S82.02. Maximum Transient Overvoltage: 240 VAC for 10 
Seconds. 

CE: 

Complies with EN 61326 Class A; EN61010-1 

Protection Class: Class II, Double Insulated 
Power requirements:  

Single 9 V battery (ANSI/NEDA 1604A or IEC 6LR61) 

Size:  

34.9 mm H x 87 mm W x 187 mm L 
(1.55 in H x 3.41 in W x 7.35 in L); 
With holster and Flex-Stand: 52 mm H x 98 mm W x 201 mm L (2.06 in H x 
3.86 in W x 7.93 in L) 

Weight:  

369 g (13 oz);  
With holster and Flex-Stand: 624 g (22 oz) 

Contacting Fluke 

To contact Fluke for product information, operating assistance, service, or to get 
the location of the nearest Fluke distributor or service center, call: 

USA:  1-888-99-FLUKE (1-888-993-5853) 
Canada:  1-800-36-FLUKE (1-800-363-5853) 
Europe:  +31 402-675-200 
Japan:  +81-3-3434-0181 
Singapore:  +65-738-5655 
Anywhere in the world:  +1-425-446-5500 

Or visit Fluke's web site at: 

www.fluke.com

.  

Register your Calibrator at: 

http://register.fluke.com

.  

Address correspondence to: 

Fluke Corporation 

Fluke Europe B.V. 

P.O. Box 9090, 

P.O. Box 1186, 

Everett, WA 98206-9090 

5602 BD Eindhoven 

U.S.A. The 

Netherlands 

 

Limited Warranty & Limitation Of Liability 

This Fluke product will be free from defects in material and workmanship for 3 years from 
the date of purchase. This warranty does not cover fuses, disposable batteries, or damage 
from accident, neglect, misuse, alteration, contamination, or abnormal conditions of 
operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s 
behalf. To obtain service during the warranty period, contact your nearest Fluke authorized 
service center to obtain return authorization information, then send the product to that 
Service Center with a description of the problem. 
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS 
FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE 
FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, 
ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the 
exclusion or limitation of an implied warranty or of incidental or consequential damages, 
this limitation of liability may not apply to you. 

11/99 

 

Shop for Fluke products online at:

1.888.610.7664

www.

MyFlukeStore

.com

Summary of Contents for 717 1000G

Page 1: ...ors hereafter the Calibrator include 717 1G 717 30G 717 100G 717 300G 717 500G 717 1000G 717 1500G 717 3000G 717 5000G Full Scale Pressure sensor is as listed in the Specifications section under Pressure Specifications The Calibrator is an IEC 61010 CAT I 30 V Pollution Degree 2 instrument A CAT I instrument is designed to protect against transients from low energy sources like for example electro...

Page 2: ...atibility Table 1 Pressure Unit and Range Compatibility Units Range Units Range psi All kPa All inH2O Through 3000 psi inHg All cmH2O Through 1000 psi mmHg Through 3000 psi bar 15 psi and above kg cm 2 15 psi and above mbar Through 1000 psi Symbols Symbol Meaning ON OFF button J Earth ground W Caution Important information See instruction sheet X Hazardous voltage risk of electric shock f Pressure...

Page 3: ...damage to the unit under test put the Calibrator in the correct mode before connecting the test leads When making connections connect the COM test lead before the live lead when disconnecting disconnect the live lead before the COM lead Never use the Calibrator with the case open Make sure the battery door is closed before you use the Calibrator Replace the battery as soon as the M low battery sym...

Page 4: ...essure Press U to select a different unit When you turn the Calibrator OFF the next time you turn the Calibrator back ON it returns to the pressure unit you last used The lower part of the display shows the current up to 24 mA applied to the current mA inputs See Figure 2 Power Saver The Calibrator automatically turns off after 30 minutes of inactivity To reduce this time or disable this feature 1...

Page 5: ...ALIBRATOR Current mA measurement Pressure measurement Pressure module input Pressure sensor input Current input On Off Button a I 69 mPa RANGE 83 TO 690 kPa 12 TO 100 PSI MAX 200 PSI 1 4 mP qo005f eps Figure 2 The Pressure Calibrator 717 100G is Shown Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 6: ...the display The gsymbol appears on the display Press h again to resume normal operation In ZERO mode press to decrease barometric pressure Switch Test To perform a switch test do the following Note This example uses a normally closed switch The procedure is the same for an open switch but the display reads OPEN instead of CLOSE 1 Connect the Calibrator mA and COM terminals to the switch using the ...

Page 7: ...s 1 bar 750 mmHg 1 mmHg 0 0013332 bar 1 psi 2 036 inHg 1 inHg 0 49115 psi Sourcing Loop Voltage To use the Calibrator to supply loop power 24 V dc to a current transmitter that is disconnected from the system 1 With power off hold down Uwhile pressing OON The LOOP POWER icon appears on the display 2 With the transmitter disconnected from normal loop power connect the Calibrator in series with the ...

Page 8: ...n and exit Calibrating a P I Transmitter To calibrate a P I pressure to current transmitter 1 Open the pump vent and zero the Calibrator before applying pressure Repeat frequently to ensure accuracy 2 Apply a pressure to the transmitter and measure the transmitter s current loop output OL overload is displayed at full scale 3 Connect the Calibrator to the transmitter as shown in Figure 4 or Figure...

Page 9: ...OM mA 30V MAX 100psi 689kPa RANGE MAX LOOP POWER BAROMETRIC ADJ 717 100G PRESSURE CALIBRATOR S I G N A L T E S T Red Black I 69 T T SWITCH TEST mA MODE MIN MAX ENTER qo002f eps Figure 4 Connecting to an Internal Pressure Sensor Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 10: ...COM mA 30V MAX 100psi 689kPa RANGE LOOP POWER BAROMETRIC ADJ 717 100G PRESSURE CALIBRATOR MIN MAX mA MODE SWITCH TEST a I 69 mPa RANGE 83 TO 690 kPa 12 TO 100 PSI MAX 200 PSI 1 4 mP ENTER qo006f eps Figure 5 Connecting to a Pressure Module Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 11: ...eturned for a fixed fee Cleaning Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents Calibration Calibrate your Calibrator yearly to ensure that it performs to specification A Calibration Manual Fluke PN 686540 is available Replacing the Battery XW Warning To avoid false readings which could lead to electric shock or injury replace the battery as soon as M l...

Page 12: ...it07f eps Figure 6 Battery Installation Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 13: ...7 1 B 717 300G Top Case Decal 2547021 1 B 717 500G Top Case Decal 2547039 1 B 717 1000G Top Case Decal 2547042 1 B 717 1500G Top Case Decal 2547056 1 B 717 3000G Top Case Decal 2547063 1 B 717 5000G Top Case Decal 2547074 1 C Keypad 2113087 1 D Spacer for pressure input 687449 1 E O ring for pressure input 146688 1 F 9 V battery ANSI NEDA 1604A or IEC LR61 614487 1 G Case bottom 2397526 1 Figure 7...

Page 14: ...acement Parts and Accessories cont Specifications Accuracy is specified for 1 year after calibration at operating temperatures of 10 C to 55 C Pressure Specifications Model Range SI Range Metric Max SI Max Metric 717 1G 1 to 1 PSI 7 to 7 kPa 5 PSI 34 5 kPa 717 30G 12 to 30 PSI 83 to 207 kPa 60 PSI 413 kPa 717 100G 12 to 100 PSI 83 to 690 kPa 200 PSI 1379 kPa or 1 4 mPa 717 300G 12 to 300 PSI 83 to...

Page 15: ...tion Accuracy of Reading Counts 24 mA 0 001 mA 0 015 2 Overload protection Fuseless overvoltage protection Temperature coefficient 0 005 of range per C for temperature ranges of between 10 C to 18 C and 28 C to 55 C Loop Supply 24 V dc nominal General Specifications Maximum voltage applied between either an mA terminal and earth ground or between the mA terminals 30 V Storage temperature 40 C to 6...

Page 16: ...Europe B V P O Box 9090 P O Box 1186 Everett WA 98206 9090 5602 BD Eindhoven U S A The Netherlands Limited Warranty Limitation Of Liability This Fluke product will be free from defects in material and workmanship for 3 years from the date of purchase This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of ope...

Reviews: