Fluke 5514B-70M User Manual Download Page 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use 

and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, 

and services are warranted for 90 days. This warranty extends only to the original buyer or end-user 

customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any 

product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by 

accident or abnormal conditions of operation or handling. Fluke warrants that software will operate 

substantially in accordance with its functional specifications for 90 days and that it has been properly 

recorded on non-defective media. Fluke does not warrant that software will be error free or operate 

without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers 

only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is 

available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the 

applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/

replacement parts when product purchased in one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge 

repair, or replacement of a defective product which is returned to a Fluke authorized service center within 

the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return 

authorization information, then send the product to that service center, with a description of the difficulty, 

postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following 

warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke 

determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal 

condition of operation or handling, including overvoltage failures caused by use outside the product’s 

specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of 

repair costs and obtain authorization before commencing the work. Following repair, the product will be 

returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return 

transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER 

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY 

SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF 

DATA, ARISING FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or 

limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not 

apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other 

decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any 

other provision.

11/99

Fluke Corporation

P.O. Box 9090

Everett, WA 98206-9090

U.S.A.

1.888.610.7664 

[email protected]

Fluke-Direct

.com

Summary of Contents for 5514B-70M

Page 1: ...ump Users Manual April 2021 English 2021 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies 1 888...

Page 2: ...ur nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FO...

Page 3: ...libration 1 Safety Information 1 Specifications 2 Operating Fluid Compatibility 2 DUT Connection 3 Operation 4 Priming 4 Pressure Operation 4 Ancillary Equipment 5 Pointer Remover Punch P5551 5 Master...

Page 4: ...ii P5514B 70M P5514B 70M EP Users Manual 1 888 610 7664 sales GlobalTestSupply com Fluke Direct com...

Page 5: ...is document refer to any pressure measuring instrument such as Transfer Standards Digital Calibrators and Transducers The Fluke 700G and 2700G Digital Test Gauges are recommended for this application...

Page 6: ...trument check the quality of the operating fluid during use If the fluid becomes discolored cloudy or particles appear in the reservoir drain and flush the system with clean fluid Pressure Range 70 MP...

Page 7: ...face of the device to be fitted is clean and undamaged as scratches or dents can form leak paths To connect the DUT 1 Select the appropriate adapter from the adapter set to match the thread on the DUT...

Page 8: ...ssure Operation Follow these steps 1 Turn the screw press in to generate pressure 2 Allow a few moments for the system to stabilize before taking any readings especially after large changes in system...

Page 9: ...can damage the sensitive instruments attached to the system Ancillary Equipment Pointer Remover Punch P5551 To remove and refit the pointer of a pressure gauge use the pointer remover punch instrument...

Page 10: ...s in Table 2 for detailed lists of available ranges and specifications Table 2 Gauges Figure 2 Fluke 700G Model Nominal Specification 700G See Figure 2 0 05 FS 700RG 0 04 Reading 0 01 FS 2700G 0 02 FS...