Fluke 435-II Technical Data Manual Download Page 8

Ordering information

Fluke-434-II 

Three-Phase Energy Analyzer

Fluke-435-II 

Three-Phase Power Quality and Energy Analyzer

Fluke-437-II 

400 Hz Three-Phase Power Quality and Energy Analyzer

Optional/replacement accessories 

I430-FLEXI-TF-4PK  6000 A Fluke 430 Thin Flexi 61 cm (24 in) 4 pack

C437-II 

Hard Case 430 Series II with roller

C1740 

Softcase for 174X and 43X-II PQ Analyzer

i5sPQ3 

i5sPQ3, 5 A ac Current Clamps, 3-pack

i400s 

i400s AC Current Clamp

WC100  

WC100 Color Localization Set

GPS430-II 

GPS430 Time Synchronization Module

BP291  

Double capacity Li-ion battery (up to 16 hr)

HH290  

Hanging hook for use on cabinet doors

Fluke Corporation

 

PO Box 9090, Everett, WA 98206 U.S.A.

Fluke Europe B.V.

 

PO Box 1186, 5602 BD  

Eindhoven, The Netherlands

Fluke. 

Keeping your world up and running.

®

For more information call:

 

In the U.S.A. (800) 443-5853 or  

Fax (425) 446-5116 

In Europe/M-East/31 (0) 40 2675 200 or  

Fax +31 (0) 40 2675 222 

In Canada (800)-36-FLUKE or  

Fax (905) 890-6866 

From other cou1 (425) 446-5500 or  

Fax +1 (425) 446-5116 

Web access: http://www.fluke.com

©2006, 2011 Fluke Corporation.  

Specifications subject to change without notice.  

Printed in U.S.A. 8/2011 2643006D D-EN 

Pub ID 11858-eng

Modification of this document is not 

permitted without written permission 

from Fluke Corporation.

Flexible Current Probe i430 Flexi-TF specification

General specifications
Probe and cable material

Alcryn 2070NC, reinforced insulation, UL94 V0, Color: RED

Couplings material

Lati Latamid 6H-V0 Nylon

Probe cable length

610 mm (24 in)

Probe cable diameter

12.4 mm (0.49 in)

Probe cable bend radius

38.1 mm (1.5 in)

Output cable length

2.5 meters RG58

Output connector

Safety BNC connector

Operating range

-20 °C to +90 °C

Storage temperature

-40 °C to +105°C

Operating humidity

15 % to 85 % (non condensing)

Degree of protection (Probe)

IP41

Specifications
Current range

6000 A AC RMS

Voltage output (@1000 ARMS, 50 Hz)

86.6 mV

Accuracy

± 1 % of reading (@ 25 °C, 50 Hz)

Linearity (10 % to 100 % of range)

± 0.2 % of reading

Noise (10 Hz – 7 kHz)

1.0 mV ACRMS

Output impedance

82 Ω min

Load impedance

50 MΩ

Internal Resistance per 100 mm probe 

length

10.5Ω ± 5 %

Bandwidth (-3dB)

10 Hz to 7 kHz

Phase error (45 Hz – 65 Hz)

± 1°

Position sensitivity

± 2 % of reading max.

Temperature coefficient

± 0.08 % max of reading per °C

Working voltage  

(see safety standards section)

1000 V AC RMS or DC (head) 

30 V max. (output)

Shop for Fluke products online at:

1.877.766.5412

www.

MyFlukeStore

.com

Summary of Contents for 435-II

Page 1: ...models capture 100 120 cycles 50 60Hz of each event that is detected in all modes without set up Automatic Transient Mode 435 and 437 Series II analyzers capture 200 kHz waveform data on all phases s...

Page 2: ...fect of unevenly loading each phase in three phase systems Unbalance can often be corrected by reconnect ing loads on different phases to ensure the current drawn on each phase is as equal as possible...

Page 3: ...luded i430flex TF with sensitivity 10x 5 Arms to 6000 Arms with included i430flex TF with sensitivity 1x 0 1 mV A to 1 V A and custom for use with optional ac or dc clamps Input impedance 1 M Bandwidt...

Page 4: ...z Transients 435 II and 437 II only Transient waveforms 4x Voltage 4x Amps triggers Vrms Arms Pinst Mains Signaling 435 II and 437 II only Relative signaling voltage and absolute signaling voltage ave...

Page 5: ...mV A 1x 5 A to 2000 A 1A 0 5 5 counts 1mV A 10x 0 5 A A to 200 A ac only 0 1 A 0 5 5 counts Hz Hz Fluke 434 50 Hz nominal 42 50 Hz to 57 50 Hz 0 01 Hz 0 01 Hz Fluke 434 60 Hz nominal 51 00 Hz to 69 00...

Page 6: ...alue over 10 12 cycle period var Fundamental reactive power display Calculates reactive power on fundamental positive sequence components Capacitive and inductive load is indicated with capacitor and...

Page 7: ...g and Monitor Mode for nominal voltage 50 V to 500 V Wiring configurations 1 NEUTRAL Single phase with neutral 1 SPLIT PHASE Split phase 1 IT NO NEUTRAL Single phase system with two phase voltages wit...

Page 8: ...subject to change without notice Printed in U S A 8 2011 2643006D D EN Pub ID 11858 eng Modification of this document is not permitted without written permission from Fluke Corporation Flexible Curre...