SW43W
Users Manual
18
2.
Choose for example
Voltage
(Fluke43B)
or
Voltage A/L1
(Fluke 43x).
3.
Click
Start
to read and display the selected waveforms.
To change the window to your preference see Window Properties on page 15.
Fluke 43x waveform example:
Datablock
Cursor Values
Name
: Name of the waveform
Date
: Start date of the waveform
Time
: Start time of the waveform
Y Scale
: Vertical scale
Y At 50
: Vertical position
X Scale
: Horizontal scale
X At 0%
: Horizontal position
X Size
: Shown (Total) number of
waveform points
Maximum :
Maximum
value
Minimum :
Minimum
value
X1 : Time at cursor 1
X2 : Time at cursor 2
dX :
X2
-
X1
Y1 : Minimum and maximum value at cursor 1
Y2 : Minimum and maximum value at cursor 2
dY : Minimum and maximum Y2 - Y1
Notice that values apply to the active waveform.
Note
The Date and Time formats depend on the Windows® settings.
Tip
Right click in the window to see the View/Options menu, for example to
show or hide the datablock, cursors and description.
Window Title