Fluke 393 FC Quick Start Manual Download Page 3

 

3    Fluke Corporation     Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads

https://www.fluke.com/en-us/product/electrical-testing/clamp-meters/solar-tools-393-irrsol

Distance from Optimum

i2500-10 Flex

i2500-18 Flex

Error

A

0.5 in (12.7 mm)

1.4 in (35.6 mm)

±0.5 %

B

0.8 in (20.3 mm)

2.0 in (50.8 mm)

±1.0 %

C

1.4 in (35.6 mm)

2.5 in (63.5 mm)

±2.0 %

Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature

range.

 

 

 

 

DC Current

 

 

 

Range

999.9 A

 

 

Resolution

0.1 A

 

 

Accuracy

2 % RD + 5 digits

[1]

 

 

 

[1]

 When using the ZERO (B) function to compensate for offsets.

AC Voltage

 

 

 

Range

600.0 V

 

 

 

1000 V

 

 

Resolution

0.1 V (≤600.0 V)

 

 

 

1 V (≤1000 V)

 

 

Accuracy

1 % RD + 5 digits (20 Hz to 500 Hz)

 

DC Voltage

 

 

 

Range

600.0 V

 

 

 

1500 V

 

 

Resolution

0.1 V (≤600.0 V)

 

 

 

1 V (≤1500 V)

 

 

Accuracy

1 % RD + 5 digits

 

 

mV dc

 

 

 

Range

500.0 mV

 

 

Resolution

0.1 mV

 

 

Accuracy

1 % RD + 5 digits

 

 

Amps Frequency: Jaw

 

 

 

Range

5.0 Hz to 500.0 Hz

 

 

Resolution

0.1 Hz

 

 

Accuracy

0.5 % RD + 5 digits

 

 

Trigger Level

5 Hz to 10 Hz, ≥10 A

 

 

 

10 Hz to 100 Hz, ≥5 A

 

 

 

100 Hz to 500 Hz, ≥10 A

 

 

Amps Frequency: Flexible Current Probe

 

 

 

Range

5.0 Hz to 500.0 Hz

 

 

Resolution

0.1 Hz

 

 

Accuracy

0.5 % RD + 5 digits

 

 

Trigger Level

5 Hz to 20 Hz, ≥25 A

 

 

 

20 Hz to 100 Hz, ≥20 A

 

 

 

100 Hz to 500 Hz, ≥25 A

 

 

Summary of Contents for 393 FC

Page 1: ...lex is an industrial clamp meter designed for solar photovoltaic PV installation technicians and maintenance professionals who work in high voltage dc environments Safely connect the MC4 test leads to...

Page 2: ...rminal and Earth Ground AC 1000 V DC 1500 V Batteries 2 AA IEC LR6 alkaline Display Dual display with backlight Automatic Power Off 20 minutes Electrical Accuracy Accuracy is specified for 1 year afte...

Page 3: ...nt Range 999 9 A Resolution 0 1 A Accuracy 2 RD 5 digits 1 1 When using the ZERO B function to compensate for offsets AC Voltage Range 600 0 V 1000 V Resolution 0 1 V 600 0 V 1 V 1000 V Accuracy 1 RD...

Page 4: ...ution 0 1 600 0 1 6000 0 01 k 60 00 k Accuracy 1 RD 5 digits Capacitance Range 100 0 F 1000 F Resolution 0 1 F 100 0 F 1 F 1000 F Accuracy 1 RD 5 digits Inrush Trigger Level 5 A Mechanical Size L x W...

Page 5: ...tice of it This equipment is intended for use in business environments and not to be used in homes USA FCC 47 CFR 15 subpart B This product is considered an exempt device per clause 15 103 Safety Gene...

Page 6: ...tic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes There may be potential difficulties in ensuring electromagnetic compatibility...

Page 7: ...r Test Leads https www fluke com en us product electrical testing clamp meters solar tools 393 irrsol Contact Brass Nickel Plated Brass Nickel Plated Length 60 36 12 Voltage CAT III 1000V CAT III 1000...

Page 8: ...1500 V TRMS clamp meter Test leads CAT III 1500 V rated right angle plugs with safety caps iFlex 18 inch flexible current probe TPAK magnetic hanging strap Premium carrying case 3 year warranty FLK IR...

Page 9: ...425 446 5500 www fluke com 2022 Fluke Corporation Specifications subject to change without notice 12 2022 Modification of this document is not permitted without written permission from Fluke Corporat...

Reviews: