2    Fluke Corporation     Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads

https://www.fluke.com/en-us/product/electrical-testing/clamp-meters/solar-tools-393-irrsol

DC power measurement, showing readings in kVA
Logging and reporting of test results via Fluke Connect software
Make instantaneous measurements to determine the watts per square meter solar irradiation, required by IEC 62446-1
standard
MC4 leads comply to IEC / EN 61010-031

Specifications: Solar Tools Kit with 393 FC Clamp Meter, Irradiance
Meter and Solar Test Leads

Specifications: Fluke 393 FC CAT III 1500 V True-rms Solar Clamp Meter

General

 

 

 

Maximum voltage between any Terminal and Earth Ground

 

 

AC

1000 V

 

 

DC

1500 V

 

 

Batteries

2 AA IEC LR6 alkaline

 

 

Display

Dual display with backlight

 

 

Automatic Power Off

20 minutes

 

 

Electrical

 

 

 

Accuracy

 

 

 

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form

of: ±([% of Reading] + [Number of Least Significant Digits]).

Temperature Coefficients

Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C

AC Current: Jaw

 

 

 

Range

999.9 A

 

 

Resolution

0.1 A

 

 

Accuracy

2 % + 5 digits (10 Hz to 100 Hz)

 

 

2.5 % + 5 digits (100 Hz to 500 Hz)

 

Crest Factor (50/60 Hz)

2.5 @600.0 A

 

 

 

3.0 @500.0 A

 

 

 

1.42 @999.9 A

 

 

 

Add 2 % for C.F. >2

 

 

AC Current: Flexible Current Probe

 

 

 

Range

999.9 A

 

 

 

2500 A

 

 

Resolution

0.1 A (≤999.9 A)

 

 

 

1 A (≤2500 A)

 

 

Accuracy

3 % RD + 5 digits (10 Hz to 500 Hz)

 

Crest Factor (50/60Hz)

2.5 @1400 A

 

 

 

3.0 @1100 A

 

 

 

1.42@2500 A

 

 

 

Add 2 % for C.F. >2

 

 

Position Sensitivity

 

 

 

Summary of Contents for 393 FC

Page 1: ...lex is an industrial clamp meter designed for solar photovoltaic PV installation technicians and maintenance professionals who work in high voltage dc environments Safely connect the MC4 test leads to...

Page 2: ...rminal and Earth Ground AC 1000 V DC 1500 V Batteries 2 AA IEC LR6 alkaline Display Dual display with backlight Automatic Power Off 20 minutes Electrical Accuracy Accuracy is specified for 1 year afte...

Page 3: ...nt Range 999 9 A Resolution 0 1 A Accuracy 2 RD 5 digits 1 1 When using the ZERO B function to compensate for offsets AC Voltage Range 600 0 V 1000 V Resolution 0 1 V 600 0 V 1 V 1000 V Accuracy 1 RD...

Page 4: ...ution 0 1 600 0 1 6000 0 01 k 60 00 k Accuracy 1 RD 5 digits Capacitance Range 100 0 F 1000 F Resolution 0 1 F 100 0 F 1 F 1000 F Accuracy 1 RD 5 digits Inrush Trigger Level 5 A Mechanical Size L x W...

Page 5: ...tice of it This equipment is intended for use in business environments and not to be used in homes USA FCC 47 CFR 15 subpart B This product is considered an exempt device per clause 15 103 Safety Gene...

Page 6: ...tic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes There may be potential difficulties in ensuring electromagnetic compatibility...

Page 7: ...r Test Leads https www fluke com en us product electrical testing clamp meters solar tools 393 irrsol Contact Brass Nickel Plated Brass Nickel Plated Length 60 36 12 Voltage CAT III 1000V CAT III 1000...

Page 8: ...1500 V TRMS clamp meter Test leads CAT III 1500 V rated right angle plugs with safety caps iFlex 18 inch flexible current probe TPAK magnetic hanging strap Premium carrying case 3 year warranty FLK IR...

Page 9: ...425 446 5500 www fluke com 2022 Fluke Corporation Specifications subject to change without notice 12 2022 Modification of this document is not permitted without written permission from Fluke Corporat...

Reviews: