Display Screen
21
Table 3. Screen Abbreviations
Screen Usage
Name and Description
°
d
Phase Angle degrees. (
±
180
°
)
Measures time from the positive zero crossing of the
fundamental of the selected volts or amp
P
REF. 360
°
represents one cycle at the fundamental or selected
harmonic frequency. A positive sign indicates that the
positive zero crossing of the measured cycle comes
earlier than (leads) that of the reference.
Note
For the Watts
h
screen, the phase angle always shows the
relation of Amps to the Volts
PREF at the same frequency. Cos
φ
calculations are based on this definition.
A RMS
Amps RMS (includes dc component if using dc capable
current probe).
A PK
Peak Amps (1/2 peak-to-peak value).
A DC
Amps DC.
A HM
For a current waveform, A HM identifies the total
harmonic current present.
A LEAD
Amps Lead Volts
Evidence of capacitive reactance in the system; the
current waveform precedes the voltage waveform.
A LAG
Amps Lag Volts
Evidence of inductive reactance in the system; the
current waveform occurs after the voltage waveform.
CF
Crest Factor
Ratio of a waveform’s peak value to its rms value.
Summary of Contents for 39
Page 4: ......
Page 36: ...39 41B Users Manual 26 a10c eps Figure 10 Waveform Screens ...
Page 38: ...39 41B Users Manual 28 a12c eps Figure 11 Harmonics Screens ...
Page 42: ...39 41B Users Manual 32 a13c eps Figure 14 Text Screens ...
Page 46: ...39 41B Users Manual 36 V A W a15c eps Figure 16 Record Screens ...
Page 74: ...39 41B Users Manual 64 ...