FW-N410-P-M_v0203_01_EN
Page 12
▪
Interrupting and ending the batch process
1. Press HOLD: Interrupts the batch process temporarily, the pump stays on and the actual
data is kept while the display shows HOLD (flashing).
2. Press HOLD, START, The interrupted batch is resumed.
OR:
Press HOLD, RESET: Stops the batch process at any time, the batch sequence is ended as
a completed batch and the remaining quantity of the batch is ignored.
3. When the batch is stopped and the display shows READY, press RESET for 3 seconds.
You can start a new batch when the display shows 0.
Figure 7: Example display information when interrupted.
▪
Power failure during a batch process
When during a batch a power failure occurs, the latest batch information is saved and made
available again at power-up. It is not possible to resume the batch. After the power failure, the
display will show “powerfail”. Before a new batch is possible, the user must confirm the power
failure by pressing the reset-key.
The following information is available on request:
▪
Flowrate indication
During batching, the actual flowrate will be displayed after pressing the RATE-key. To return
to the main display: press RATE again or wait for 20 seconds.
▪
Display total and accumulated total
When the TOTAL-key is pressed once, the resettable total will be displayed. After pressing
this key again, the accumulated total will be displayed.
The accumulated total cannot be reset. The value will count up to 9,999,999,999. The
measurement unit and the number of decimals are displayed according to the configuration
settings for preset. To return to the main display: press TOTAL again or wait for 20 seconds.
▪
Clear total
Total can only be reset if no batch process is active (status: READY).
This function might not be available due to configuration settings.
The value for total can be re-initialized. To do so, select Total and press RESET:
the flashing text "PUSH RESET" will be displayed.
To avoid a reset at this stage, press another key than RESET or
wait for 20 seconds. If RESET is pressed again, TOTAL will be reset to zero.
The reset of total DOES NOT influence the accumulated total.
▪
Display batch counter
The number of completed batches is displayed after pressing COUNT. To return to the main
display: press COUNT again or wait for 20 seconds.