Page 47
FW_F127PELTP_v1702_02_EN
PDU
ADDRESS
REGISTER VARIABLE
ANALOG OUTPUT
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 112
[h] 0x070
40113
analog output
1
r/w
uint16 0: disable
1: enable
[d] 113
[h] 0x071
40114
rate-min
2
r/w
uint32 0…9999999
Representation: unit, time, decimals depending
on variables 48, 49, 50
[d] 116
[h] 0x074
40117
rate-max
2
r/w
uint32 0…9999999
Representation: unit, time, decimals depending
on variables 48, 49, 50
[d] 119
[h] 0x077
40120
cut off
1
r/w
uint16 0...99
Representation: 0.0 – 9.9%
[d] 120
[h] 0x078
40121
tune-min
1
r/w
uint16 0...9999
[d] 122
[h] 0x07A
40123
tune-max
1
r/w
uInt16 0...9999
[d] 99
[h] 0x063
40100
filter
1
r/w
uint16 1...99
PDU
ADDRESS
REGISTER VARIABLE
PULSE
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 135
[h] 0x087
40136
mode
1
r/w
uint16 0: not negative
1: separated
2: signed
[d] 128
[h] 0x080
40129
pulse width
1
r/w
uint16 0…9999, (0=disabled)
Representation: 0.000 – 9.999 sec
[d] 133
[h] 0x085
40134
decimals
1
r/w
uint16 0…3
[d] 130
[h] 0x082
40131
amount
2
r/w
uint32 1...9999999
Representation: 0.001…9999999
depending on variables 133
PDU
ADDRESS
REGISTER VARIABLE
COMMUNICATION
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 144
[h] 0x090
40145
speed (baud rate)
1
r/w
uint16 0: 1200
1: 2400
2: 4800
3: 9600
[d] 145
[h] 0x091
40146
Modbus address
1
r/w
uint16 1…247
[d] 146
[h] 0x092
40147
Modbus mode
1
r/w
uint16 0=ASCII
1=RTU
2=OFF
PDU
ADDRESS
REGISTER VARIABLE
OTHERS
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 173
[h] 0x0AD
40174
model number
1
r
uint16 0…9999
[d] 160
[h] 0x0A0
40161
model suffix
1
r
char
Representation: ASCII character
[d] 162
[h] 0x0A2
40163
firmware version
2
r
uint32 0…999999
Representation: nn:nn:nn
[d] 165
[h] 0x0A5
40166
serial no
2
r
uint32 0…9999999
Representation: nnnnnnn
[d] 168
[h] 0x0A8
40169
password
1
r
uint16 0…9999
[d] 170
[h] 0x0AA
40171
tag-nr
2
r/w
uint32 0...9999999
Representation: nnnnnnn