VAR DESCRIPTION
BYTES VALUE
REMARKS
PRESSURE
544
(220h)
unit 1
0=mbar
1=bar
2=psi
3=no unit
546
(222h)
span 3
1....9,999,999
549
(225h)
decimals span
1
0…6
550
(226h)
offset
3
0.000....9,999.999 unit as var544
step 0.001
90
(5Ah)
calibration low
(4mA)
1 0=default
1=calibrate
2=cal set
91
(5Bh)
calibration high
(20mA)
1 0=default
1=calibrate
2=cal set
89
(59h)
filter 1
0….99
FORMULA
537
(219h)
normal temperature 3
0.00....99,999.99
step: 0.01 K
555
(229h)
normal pressure
3
0.000....9,999.999 unit as var544
step 0.001
227
(E3h)
compressibility 3 0....9,999,999
40
(28h)
normal compress.
3
0....9,999,999
ANALOG OUTPUT
112
(70h)
analog output
1
0=disable
1=enable
113
(71h)
minimum rate
3
0..9999999
unit, time, decimals acc. var48-50
116
(74h)
maximum rate
3
0..9999999
unit, time, decimals acc. var48-50
119
(77h)
cut off percentage
1
0..99
steps of 0.1%
120
(78h)
tune minimum rate
2
0..9999
122
(7Ah)
tune maximum rate 2
0..9999
117
(7Fh)
filter 1
0….99
OTHERS
01
(1h)
Model 2
read
only!
06
(6h)
Software version
2
read only!
02
(2h)
Serial number
4
read only!
168
(A8h)
password 2
xxxx
read
only!
170
AAh
tagnumber
3
0..9999999
Other vars: see standard table