HF070AEN_v0403_03 Atex_IECEx_CSA_FM
Page 23
4.4.3. TERMINAL
CONNECTORS
WITH POWER SUPPLY - TYPE : PF / PM
For Intrinsically Safe applications: read chapter 5.
The following terminal connectors are available:
Fig. 9: Overview of terminal connectors F070-A-(PF / PM) and options.
SENSOR SUPPLY
Type PF-PM: Sensor supply: 8.2V, 12V or 24 V:
With this option, a real power supply for the sensor is available. The sensor can be powered with
8.2, 12 or 24 V DC (max. 400mA@24V).
The voltage is selected with the three switches inside the enclosure.
Warning: be sure that all the leads to the terminals are disconnected from the unit when
the internal plastic protection cover has been removed !
HIGH VOLTAGE 400V !! NEVER connect the mains power supply to the unit when the
plastic protection cover has been removed !!!
First, remove the terminal strip(s) after which the internal plastic cover can be removed. The
switches are located on the right hand (option PF / PM) as indicated:
Fig. 10: switch position voltage selection (type PF and PM).
Switch positions / sensor supply voltage
VOLTAGE SELECTION
SWITCH
8.2V
DC 12V
DC 24V
DC
J1
off
off
off
J2
on
on
off
J3
on
off
on or off
GND
1
POWER SUPPLY
TYPE:
PF / PM
N
L1
2
SENSOR SIGNAL
TYPE: A
ANALOG (0)4-20mA
+
6
5
7
I
J3
PF / PM
J2
J1