5.2.5
ELECTRICAL DATA
– ANNEX 1
Annex 1
(model specific)
to product certificates KEMA 03ATEX1168 X, IECEx DEK 08.0006X, DEKRA 21UKEX0202 X.
Model F0..-A-XI
Model F0..-A-PL-XI
Internal supply
Type -PC
(connector)
for use with the certified replaceable battery type FW-LiBAT-
… or to
another certified non rechargeable battery in type of protection
intrinsic safety Ex ia IIC/IIIC, with the following maximum values:
U
i
=
4 V
Ii
=
50 mA
Pi = 200 mW
L
i
=
0 mH
C
i
=
0
μF
Analog input circuit
(terminals 1 and 2)
Analog input circuit
Loop powered analog input circuit
in type of protection intrinsic safety Ex ia IIC/IIIC, only for connection
to a certified intrinsically safe circuit, with following maximum values:
U
i
=
30 V
I
i
= 150 mA
P
i
= 0.92 W
L
i
=
0 mH
C
i
=
0 nF
U
i
=
30 V
I
i
=
93 mA
P
i
= 0.92 W
L
i
=
0 mH
C
i
=
0 nF
Reference output circuit
(terminals 3 and 1 or 2)
in type of protection intrinsic safety Ex ia IIC/IIIC, with the following
maximum values:
Not applicable
External supply input circuit
Type -PD, -PX
(terminals 4 and 5)
in type of protection intrinsic safety Ex ia IIC/IIIC, only for connection
to a certified intrinsically safe circuit, with following maximum values:
Ui =
30 V
Ii
= 200 mA
Pi =
1.2 W
Li =
0 mH
Ci =
0 nF
External supply output circuit
Type -PD
(terminals 6 and 1, 2, 7 or 8)
in type of protection intrinsic safety Ex ia IIC/IIIC, with the following
maximum values:
The maximum output parameters are
equal to the parameters of the external
supply input circuit (terminals 4 and 5)
Pulse output circuit
Type -OT
(terminals 7 and 8)
in type of protection intrinsic safety Ex ia IIC/IIIC, only for connection
to a certified intrinsically safe circuit, with following maximum values:
Ui =
30 V
Ii
= 200 mA
Pi =
1.2 W
Li =
0 mH
Ci =
0 nF
Backlight supply input circuit
Type -ZB
(terminals 9 and 10)
in type of protection intrinsic safety Ex ia IIC/IIIC, only for connection
to a certified intrinsically safe circuit, with following maximum values:
Ui =
30 V
Ii
= 200 mA
Pi = 0.75 W
Li =
0 mH
Ci =
0 nF
Analog output
(with HART)
Type -AH
(terminals 11 and 12)
in type of protection intrinsic safety Ex ia IIC/IIIC, only for connection
to a certified intrinsically safe circuit, with following maximum values:
Ui =
30 V
Ii
= 100 mA
Pi = 0.75 W
Li =
0 mH
Ci =
6.1 nF
From the safety point of view the circuits shall be considered to be connected to earth.