background image

INST 371 VIRON QL Cartridge Filter V08-20 

 

 

 

WARNING

: To reduce the risk of injury, do not permit children to use this product unless they are closely 

supervised at all times. 
 

 

CAUTION

: This filter is for use with permanently installed pools and may be used with hot tubs and spas if so 

marked. Do not use with storable pools, A permanently installed pool is considered in or on the ground or in a building such 
that it cannot be readily

 

disassembled for storage. A storable pool is constructed so that it may be readily disassembled for 

storage and reassembled to its original integrity. 

 

GENERAL INSTALLATION INFORMATION. 
The following information should be read carefully as it outlines the proper manner of care and operation of your filter 
system. You can expect maximum efficiency and product life from you filtration system by following these instructions and 
taking the necessary preventative maintenance. 
*.Have a trained pool professional perform all pressure testing 
* Do not connect the system to a high pressure or city water systems. 
* Trapped air in the system can create a hazardous condition. MAKE SURE to purge all air from the system before operating 
or testing of the equipment. 
* DO NOT PRESSURE TEST WITH COMPRESSED AIR 
* Check local codes for restrictions on backwash to waste piping, separation tank requirements. 
* Piping must conform to local/state plumbing and sanitary codes 
* Support piping independently to prevent strains on the filter or valve 
* Fittings restrict flow, for best efficiency, use the fewest possible fittings 
* A check valve installed between the filter inlet will prevent contaminants from draining back into the Pool. 
* A check valve installed between the filter and heater will prevent hot water from backing up into the filter and deforming 
the internal components. 
* All wiring, grounding and bonding of associated equipment must meet local and/or National Electrical Code (NEC)   
standards  

GENERAL OVERVIEW 

The VIRON QL Cartridge filter features 4 easily accessible and removable filter cartridges. When water passes through these 
cartridges, microscopic impurities like dirt, algae and some forms of bacteria are filtered out, giving you water that really 
sparkles. 
The 4 cartridges design greatly increases the filter’s internal surface area, meaning a much greater cleaning capacity for every 
cycle without the need for a larger filter. After turning off and isolating the filter pump, cleaning is achieved by removing the 
clamp band, lifing off the filter lid, removing the four filter elements and hosing off dirt and debris with a high pressure hose. 

INSTALLATION  

Only a trained service person should install the VIRON QL Cartridge filter

 

WARNING 

– Risk of electrical shock or electrocution. 

Position the filter and allowing for the air/water bleed valve located in the lid to safely direct water drainage and purged air or 
water. Water discharged from an improperly position filter can create an electrical hazard that can cause severe personal injury 
as well as damage property.  

 

WARNING 

– THIS FILTER OPERATES UNDER HIGH PRESSURE 

Never subject the filter to pressure in excess of the maximum working pressure, even when conducting hydrostatic pressure 
testing. Pressures above the maximum working PSI/Kpa pressures can cause the lid to be blown off and result in severe injury, 
death or property damage  

1.

 

The filter should be mounted on a level concrete slab. Position the filter so that the instructions, warning and pressure 
gauge are visible to the operator. It should also be positioned so that the piping connections, control valve and drain 
port are convenient and accessible for servicing and winterizing. 

2.

 

Install electrical controls (timers, Chlorinators, power points) at least 6 feet from the filter. This will allow you enough 
room to stand clear of the filter during start up. 

3.

 

Allow sufficient clearance around the filter to allow visual inspection of the clamp is correctly installed around the tank 
flanges. Using a soft mallet tap the clamp to ensure uniform loading during the clamp tightening. 

4.

 

Allow enough space above the filter to remove the filter lid for cleaning and servicing. This distance should be a 
minimum of 2 feet    

5.

 

The VIRON QL Cartridge filter has 1 inlet, 2 outlets and a drain port. Either inlet can be used (top outlet height for 
other brands heaters, bottom outlet to suit HiNRG heaters. Whichever port you use the other will have to be plugged 
with plug cap supplied with filter  

6.

 

Make all plumbing connections in accordance with local plumbing and building codes. Check local codes for restrictions 
on backwash to waste piping, separation tank requirements. Allow minimum of 1 hour for glue to dry on pipe fittings 
before pressuring up the system.  

7.

 

Filter plumbing connections are provided with an o-ring seal. To avoid damage to the o-rings, use only a silicone base 
lubricant on the o-rings. Do not use a petroleum based lubricate as it will degrade the o-rings. 

Reviews: